Descargar Imprimir esta página

Technical Data - Teddington P Serie Instrucciones De Uso

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 52
Operating manual
P-Series
11.
The most frequent malfunctions – and how to do troubleshooting
Malfunction
Air curtain cannot be
turned on, indicator lamp
not lit
Air curtain cannot be
turned on, indicator lamp
lit GREEN
Air curtain cannot be
turned on, indiator lamp lit
RED
Smoke and smell
emission in case of
electrical heated air
curtain systems
12.

Technical data

P-Series 1
Dimensions
Total length [cm]
Volume flow
Volume flow [m³/h]
PWW 70/50 °C
Heater power [kW]
Through flow rate [m3/h]
Water resistance [kPA]
Air discharge temperature [20°C Tein]
Pipe connection
Upstream/downstream [Inch]
Power consumption
Voltage, 1Ph, 50 Hz [V]
Power output [kW] max.
Current [A] max.
Electrical heater power
400V/3Ph [kW]
T [K]
16
Possible cause
Building fuse is defective
Air curtain fuse is
defective
Short-term power surge
Motor overheated and/or
defective
Building fuse is defective
100
1400
7,8
0,35
3,19
35,4
¾
230
0,35
1,52
9
18
What you can do
Reset fuse in the sub-distribution
Change fuse; if the fuse burns out again, definitely
consult electrician or our customer service
Set selector switch to „zero", then set again to
selected level
Motor defective, inform customer service or HVAC
company
Turn system off, make a vacuum-clean from the
heating element and air-intake grille (if malfunction
still remains after half an hour up to three quarters of
an hour, please inform customer service)
150
200
1800
2700
11,4
16,9
0,51
0,73
4,39
6,61
37,6
37,4
¾
¾
230
230
0,49
0,74
2,14
3,21
12
18
19
19
250
300
3600
3900
22,4
25,2
1,06
1,19
8,58
6,39
37,4
38,0
¾
¾
230
230
0,99
1,02
4,28
4,42
18
24
14
17

Publicidad

loading