Fig. 8izqda: fan window in position 2 or 3, installed vibration screw.
Fig 8dcha: fan tied around his window with NTC probe caught between screw and fan frame
Chimney
Connect the H03 TURBO-CONVECTOR Wood
Burner to the chimney following the
instructions contained in chapter 2 and in the
manual for Professional Installers.
Forced convection
The air outlets from the convection chamber
must be connected using flexible tubes to the
areas where you wish to direct this flow,
either to the room where the wood burner is
installed or to other adjacent rooms.
The H03 TURBOCONVECTOR wood burner
will be supplied with half of the outlets
closed with caps (see fig. 13). This can be
used according to the number of outlets that
you need. Never leave an outlet open inside
the casing, as convection efficiency will be
lost.
It is essential that the casing which is used to
surround you H03 TURBOCONVECTOR wood
burner has a removable panel so as to be
able to access the ventilator and its
connections in the future if necessary.
The
chamber
TURBOCONVECTOR wood burner is installed
must have an air inlet in its lower section
which
is
sufficient
ventilator. Is it advisable that the air inlet of
the ventilator is carried out if possible from
outside the house or failing that from
where
the
H03
for
supplying
the
another room separate to the one where the
wood burner is installed. The grate will have
a minimum free flow section of 400 cm
which will not be able to be closed, to
prevent depressions within the chamber
which could suck in smoke from the wood
burner.
It is necessary to place a grate on the upper
section of the casing to dissipate the heat
from this chamber so as to prevent cracks
being produced in the casing due to
accumulated excess heat.
The optimum form of air distribution is to
place commercial adjustable grates on the
outlets to the various rooms, in such a way
that you can choose at any time to which
places you want to direct the flow of hot air.
7.2. OPERATION OF FORCED CONVECTION
The fan connected to the network, that will
work according to the following guidelines:
Manual mode
The control module operates the fan in four
possible operating speeds, driven by the
remote control buttons which are configured
as follows:
- A - Button: speed increases
- B - Button B: speed decreases
- C - Button: directly activates Pot. max
- D-Button: stops and auto mode
18