Descargar Imprimir esta página

Kohler K-1224-H Guia Del Usuario página 2

Ocultar thumbs Ver también para K-1224-H:

Publicidad

Idiomas disponibles

Idiomas disponibles

18"
(45.7 cm)
1-11/16"
(4.3 cm)
8-11/16" (22.1 cm)
3-1/2"
(8.9 cm)
Product Information
Applicable product:
Drop-in rim style with heater
Integral flange with heater, left drain
Integral flange with heater, right drain
Fixture*:
Bathing well:
Basin area, bottom
48" (121.9 cm) x 24" (61 cm)
Basin area, top
59" (149.9 cm) x 30" (76.2 cm)
Weight
115 lbs (52.2 kg)
To overflow:
Water depth
14" (35.6 cm)
Capacity
67 gal (253.6 L)
* Approximate measurements for comparison only.
Drop-in cutout dimensions:
64" (162.6 cm) x 34" (86.4 cm)
V
Pump: 1-speed
120
Heater: 1.5 kW
120
Minimum access panel
pump/control (required):
1014716-1-B
K-1224-*
66" (167.6 cm)
1" (2.5 cm)
2-7/8"
(7.3 cm)
3"
(7.6 cm)
K-1224-H
K-1224-LH
K-1224-RH
Hz
A
60
7.5
60
12.5
20" (50.8 cm) W x
15" (38.1 cm) H
No change in measurements if connected with drain
illustrated. (K-7161-AF or K-7161M-AF)
Recommended Faucet Area
Pump/Control Access
(if apron is not used)
20" (50.8 cm) W x
15" (38.1 cm) H
35-7/8" (91.1 cm)
20"
18-1/2"
(50.8 cm)
(47 cm)
1-1/2" OD
Required Electrical Service (2 required)
Two dedicated circuits required, each protected with Class A
Ground-Fault Circuit-Interrupter (GFCI):
Pump/control
Heater
Locate the outlets behind the whirlpool and within 24" (61 cm)
of the pump and heater.
Notes
Install this product according to the installation guide.
Floor support under this product must provide for a minimum of
43 lbs/square foot (208 kg/square meter) loading.
The apron must be installed before the finished floor and wall
materials are installed.
If installing a rim-mount faucet, make sure there is no interference
with the drain overflow and circulating system before drilling any
holes. Consult local and national codes for minimum air gap
requirements if installing a spout on the faucet deck.
This fixture conforms to ANSI Standard Z124.1.2. All dimensions
are nominal.
2
1-1/4"
(3.2 cm)
1/2" (1.3 cm)
R. Max
Integral
Flange Detail
1-1/2"
(3.8 cm)
Drop-in Rim
Detail
120 V, 15 A, 60 Hz
120 V, 15 A, 60 Hz
Kohler Co.

Publicidad

loading

Este manual también es adecuado para:

K-1224-lhK-1224-rhK-1239-hK-1239-lhK-1239-rh