NOTES:
1. The smoke alarm will be in the interconnecting mode for 60 seconds, during which the red LED light ashes.
After 60 seconds, repeat step 2 to connect the alarms. If needed, manually press the test/silence button to stop
sending out an RF signal, and the red LED will stop ashing and the alarm will enter normal status.
2. Test all your wireless smoke alarms to ensure that they are interconnected before installation.
3. A maximum of 24 wireless smoke alarms can be interconnected.
4. Note that the X S01-WR alarm can only be interconnected with other X-SENSE wireless alarms.
How to Disconnect
Press the test/silence button 4 times and the smoke alarm will beep once, then hold down the button until it beeps
once to disconnect. After disconnecting, you can connect it again to let it enter the interlinked network.

Alarm Test

The alarm must be properly attached to the mounting bracket before it can be tested.
If your X S01-WR is interconnected to other wireless smoke alarms, we recommend that every individual smoke alarm is
tested during the weekly test.
04
Test a single alarm
Test all interconnected smoke alarms
Action
Press the test/silence
Hold down the test/silence button.
button.
Indication
• The alarm will sound 3
• The initiating smoke alarm will beep continuously with the red
short quick beeps.
• The red LED will flash
• Other interconnected smoke alarms in the network will receive
once every second during
the audible signal.
• The alarm testing should be completed within 3 minutes.
NOTE: The test function accurately tests the alarm' s smoke sensing circuit without the need of test smoke. If your smoke alarm
fails to give an audible test signal, please refer immediately to the troubleshooting guide at the end of this manual.
LED fl ashing.
the signal after 5 seconds, and they will beep continuously with
the red LED fl ashing. Release the test/silence button and all the
smoke alarms will stop testing.