4. INSTALLATION METHOD
5. Fasten the back plate of the smart port
• For exposed mounting, fasten the back plate on
the wall with the 3 screws (M4×20) and plugs.
(Fig.4-5)
Back plate
Screws (M4×20)
Fig 4-5
6. Insert the smart kit with slightly strength into the
main PCB of the smart port .(Fig.4-6)
Fig 4-6
4. INSTALLATION METHOD
7.Wiring
A. For exposed mounting, two outletting positions.
Top side wire outlet
Bottom side wire outlet
B. Shielded wiring
Wiring through the wall
Wiring hole and wall hole
Diameter of wall hole:Φ20mm
Fig 4-7
Fig 4-8
GB-
3
4. INSTALLATION METHOD
Putty
Trap
Fig 4-9
CAUTION
Avoid the water enter into the smart port, use trap
and putty to seal the connectors of wires during
wiring installation. (Fig. 4-9) When under installation,
reserve certain length of the connecting wire for
convenient to take down the smart port while during
maintenance.
8.Reattach the upper part of the smart port
• After adjusting the upper case and then buckle
the upper case; avoid clamping the wiring during
installation. (Fig 4-10)
4. INSTALLATION METHOD
9. Connect the smart port to the wire controller (if
needed)
① Remove the top cover from the gap between the
top cover and bottom by a tool with flat head. (See
Fig.4-11)
② Use the connective cable to connect the wire
controller and CN3 of the smart port. (See Fig.4-12)
(refer to the Wire controller manual for details)
Fig 4-11
NOTE:
• Connection for R485 Communication wired
controller.
Putty
Trap
Fig 4-10
CN3
Fig 4-12