Descargar Imprimir esta página

PRASTEL EASY200 Manual De Instrucciones página 2

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

EASY200
1. GENERAL DESCRIPTION
EASY200 is typically used on a door, gate, automation device, etc. to guarantee access control through the recognition of an enabled card.
EASY200 accepts data from readers in Wiegand format.
Although extremely small, it can be used to directly control electrically operated locks thanks to the integrated relay with contact capacity of
5A. The internal memory can manage 250 different user codes.
2. TECHNICAL CHARACTERISTICS - CONNECTIONS
Power supply
12-24 VAC/DC
Consumption
Min. 50 mA – Max. 80 mA
Input data format
Wiegand 26 bit, Wiegand 30 bit, Wiegand 37 bit
Memory capacity
250 users
No. of output relays
1 (Timed 1s or Bistable, selectable)
Relay contact rating
5 A
Indicators
Bi-colour LED (RED / Green)
Protection class
I.P. 44
Dimensions/weight
10 x 5.5 x 2.1 cm
The cable recommended for the connection of the EASY200 reader is STP class 5 or FTP class 5 or better.
3. OPERATION
The built-in two-colour red/green LED provides all the indications necessary to identify the current
programming phase and activate the relay.
4. PROGRAMMING
Inserting codes
1.
Press the programming key.
2.
Hold the badge to be entered up to the EASY200 connected reader. Green LED flashes to
signal entry. Wait for green LED to stay fixed again before entering the next badge.
3.
Wait 30s to exit programming mode or press the key again. LED goes back to being red.
Deactivating codes
1.
Keep key pressed for 3s. LED flashes red.
2.
Hold the badge to be disabled up to the EASY200 connected reader. Red LED starts flashing
rapidly to signal badge disabled. Wait until the LED flashes slowly red again before disabling
another Badge.
3.
The time available for presenting the badge is 30s for the first code and 10s for subsequent
codes. Once this time has elapsed, the EASY200 automatically exits the disabling procedure.
The LED returns to standby condition (red steady light or green steady light depending on the
relay operating mode).
Total cancellation of all codes
Take extreme care when carrying out the following operation. It will cancel all data from the
memory.
Once the cancellation procedure has been carried out, the programming cannot be
recovered.
1.
Keep key pressed for 3s. LED flashes red.
2.
Press key again. Red LED flashes more rapidly.
3.
Total cancellation completed.
5. RELAY OPERATING MODE
1.
Press the key. LED switches from red to green.
2.
Press key and keep pressed for 3 seconds. Relay switches from mono- to bi-stable operating mode each time key is pressed. LED
signals mode change over by flashing: 1 Green Flash = Monostable; 2 Green Flashes = Bi-stable.
6. PROGRAMMING WITH GTSYSTEM
EASY200 is provided with a connector for the multifunction terminal GTSYSTEM (see figure). Using the GTSYSTEM you can:
disable keys
assign identifiers to the keys
save the content of the memory to a backup file.
Please see the user manual of GTSYSTEM.
ENGLISH
62 g
Terminal
Description
1
12-24 VAC/DC
2
3 – NO
N.O. Relay
4 – COM
COM Relay
5 – NC
N.C. Relay
6 – +9V
Reader power supply (+9 Vdc)
7 – D0
Wiegand DATA0
8 – D1
Wiegand DATA1
9 –GND
Reader power supply (GND )
ISEASY200_03_08.doc
Connector for
GTSYSTEM

Publicidad

loading