TECHNICAL DATA:

- Power supply
: 230 Vac 50-60Hz 900W (4A) max.
- Flashing light output
- Motor output
- Services power supply output : 24 Vac 3 W max.
- Safety devices and controls in BT: 24 Vdc
- Operating temperature
- Radio receiver
- Op. transmitters
- No. of devices that can be stored : 120 max.
- Board dimensions
- Dimensions of container
- Container: ABS V-0 ( IP54 ).
TERMINAL BOARD CONNECTIONS:
CN1 :
1 : 230 Vac line input (Phase).
2 : 230 Vac line input (Neutral)
3 : 230 Vac Flashing light Output (Neutral).
4 : 230 Vac Flashing light Output (Phase).
5 : Opening 230V Motor Output.
6 : Common 230V Motor Output.
7 : Closing 230V Motor Output.
CN2:
1 : Power supply to photocells ( 24Vac 3W).
2 : Power supply to photocells (GND).
3 : Control button input (NA).
4 : Common GND input
5 : Safety device input (NC).
6 : Aerial earth input.
7 : Aerial hot pole input.
: 230 Vac 50-60 Hz
100W Resistive Load max.
50W Inductive Load max.
: 230 Vac 50-60Hz 750 W max.
: -10 ÷ 55 °C
: 433.92 Mhz "narrow band"
: 12-18 Bit or Rolling Code
: 100x105 mm.
: 110x121x47 mm.

OPERATING FEATURES:

Step-by-step operation:
By using either the Radio Control, Transponder, Digital
keyboard, Smartphone or the low voltage buttons to activate the
frame, you obtain the following action:
the first impulse activates the opening mechanism until the
motor time expires or the opening limit switch is reached, the
second impulse closes the gate. If an impulse is sent before the
motor time expires or one of the two end runs are reached, the
control unit will stop both opening and closing movements. An
additional control re-starts motion in the opposite direction.
Operation with different radio control models:
Different radio control models can be programmed: store one
code (1 key) for Step-by-Step cyclic operation (Opening - Stop -
Closing); store two different codes (2 keys) for
separate controls, the first for Opening and the second for
Closing; store one code (3 "BeFree series" keys) for three
separate controls, the first for
Opening, the second for Stop and the third for Closing.
Radio control operation with 1 Key:
Using the radio control with only one key, the following function
is obtained: the first impulse commands Opening until the motor
time expires. The second impulse commands Closing of the
frame. If an impulse occurs before the motor time expires, the
control unit stops the frame. A further impulse implements the
re-starting of the motion in the opposite direction.
Radio control operation with 2 Keys:
Using the radio control with 2 keys, the following function is
obtained: the first key ("Up" associated to the Opening
direction) commands Opening until the motor time expires, and
the second key ("Down" associated to the Closing direction)
commands Closing of the frame. If the Up command is given
again during Opening, the control unit continues the Opening
motion, while if a Down command is given, the control unit
stops motion.
The same procedure is valid during the Closing phase.
Radio control operation with 3 Keys (BeFree series):
Using the BeFree series radio controls, the following function is
obtained: the Up key commands Opening until the motor time
expires, the Stop key commands Stop, and the Down key
commands Closing of the frame. If during opening or closing a
Stop command is given, the control unit commands the frame to
stop. If during opening or closing the command opposite the
present motion is given, the control unit commands to run in the
opposite direction.
Automatic closing :
The control unit closes the gate automatically without sending
additional commands.
The choice of this operating mode is described in the
instructions for setting the delay period.
Safety Device (Photocells):
The control unit allows for the connection and control of
Photocells, Tyre sensors (NC).
- DS Input (NC)
Commands from the Safety Device are ignored during opening,
whereas during closing they will reverse the direction of
movement.