Seav LRX 2035 NEW Manual Del Usuario página 8

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

The control unit allows the transmission code to be
programmed remotely, without using the SEL key on the unit
itself.
The remote transmission code can be programmed as follows:
continuously send a previously-stored radio control code for
more than 10 seconds. At this point the control unit switches to
programming mode, as described above for the CODE LED in
the main menu.
The control unit is supplied by the manufacturer with the remote
transmission code programming function disabled. If you wish
to enable the function, proceed as follows: check that extended
menu 1 is enabled (T. MOT. and T. PAUSA LEDs flash
alternately), use the SEL key to move to the flashing CODE
LED, then press the SET key: at this point the CODE LED will
light up steady and programming is complete. Repeat the
procedure to restore the previous configuration.
B) LAMP/CORT. (
Step-by-Step / Automatic operation
The control unit is supplied by the manufacturer with Automatic
mode disabled. If you wish to enable the function, proceed as
follows: check that extended menu 1 is enabled (T. MOT. and
T. PAUSA LEDs flash alternately), use the SEL key to move to
the flashing LAMP/CORT LED, then press the SET key: at this
point the LAMP/CORT LED will light up steady and
programming is complete.
Accordingly, using either the Radio Control, Transponder,
Digital keyboard, Smartphone or the low voltage push button
panel to operate the frame, you will obtain the following
function: the first impulse commands opening until the motor
time expires, the second impulse commands frame closing. If
an impulse is sent before the motor time expires, the control
unit changes the direction of motion in the opening and closing
phases. Repeat the procedure to restore the previous
configuration.
EXTENDED MENU 2
The control unit is supplied by the manufacturer with the option
of selecting only the functions listed in the main menu.
If you wish to enable the functions described in extended menu
2, proceed as follows: access extended menu 1 (as described
in the relative paragraph), then press and hold the SET key
down again for 5 seconds, after which the T. MOT. and T.
PAUSA LEDs will start flashing simultaneously. The user then
has 30 seconds to select the functions for extended menu 2
using the SEL and SET keys. After another 30 seconds the
control unit will go back to the main menu.
--------------------- EXTENDED MENU 2 -----------------
Reference LED
LED Off
A) CODE
B) LAMP/CORT
Anti-Collision (pedestrian) CH = OFF
(pedestrian) CH = ON
C) T. MOT.
Simultaneous ON/OFF flashing
D) T. PAUSA.
Simultaneous ON/OFF flashing
A) CODE ( NOT USED ) :
B) LAMP/CORT ( Anti-Collision (pedestrian) function ) :
The control unit is supplied by the manufacturer with the Anti-
collision (pedestrian) Function disabled. If you wish to enable
the function, proceed as follows: check that extended menu 2 is
enabled (T. MOT. and T. PAUSA LEDs start flashing
simultaneously), use the SEL key to move to the flashing
LAMP/CORT LED then press the SET key: at that point the
LAMP/CORT LED will light up steady and programming is
complete. The control unit will now operate in Anti-Collision
(pedestrian) mode.
If you wish to enable the Anti-Collision (pedestrian) function for
the closing phase only, repeat the operation described above,
pressing the SEL key twice (making the LAMP/CORT LED flash
) :
LED On
NOT USED
Anti-Collision
quickly). Repeat the procedure if you wish to restore the
previous configuration.
RESET :
To reset the default configuration of the control unit, press the
SEL and SET keys simultaneously; all RED indicator LEDs will
switch on and after a few seconds off again.
DIAGNOSTICS :
Control input test:
On each low voltage control input, the control unit uses a LED
signal to make the status readily known.
Operating logic: when a LED is on it means the input is closed,
when a LED is off it means the input is open.
MANAGING PROGRAMMING LEDS:
After 3 minutes of inactivity in the programming procedure, the
control unit will automatically switch off the programming LEDs
to save energy. The LEDs will light up, depending on the
previously set programs, only when the SEL or SET keys are
pressed or when a motion command has been received.
8
rev. 3.0 13/06/2016

Publicidad

Tabla de contenido
loading