CAUTION: All connections and couplings must be hand-tight. Do not tighten them with tools.
Otherwise damage may occur.
1. Unscrew the nut (N) from the housing (U). Remove the UV-C lamp (K) from the supplied tube (see
packaging) and carefully slide the lamp into the quartz sleeve (M). Place the lamp (K) with the contact
pins in the lamp fitting (L) and then tighten the nut (N) on the housing (U).
2. Fit the supplied pipe clamps (O). Then insert the unit into the pipe clamps. Tighten the three-
piece coupling (I) firmly, while ensuring the correct position of the sealing rings (P), both at the
connections and the quartz sleeve (see figure 2).
3. Mount the unit in the circuit by means of the three-piece coupling (I) and the glue coupling for the
flow switch (V *For amalgam only). The glue connections of the three-piece coupling are Ø63 mm
or 2". If the pipes are smaller than Ø63 mm or 2", use the Ø63 x 50 mm (T) or 2" x 1.5" x 1" adapter.
This can be glued in the three-piece coupling (I) and in the glue coupling for the flow switch (V *For
amalgam only). The inside of the adapter (T) has internal screw threads at one end, making it possible
to fit a hose tail adapter (not included) with sealing ring.
4. Insert the plug of the UV-C device into an earthed wall socket that is protected by a residual current
device.
5. Look through the transparent parts of the device to make sure the lamp is lit.
6. The device is shut off when power is disconnected from the device.
INSTRUCTIONS FOR USE DIGITAL HOUR METER
When the UV-C device is switched on, the program will perform a self-diagnostic test. The display
shows the following indications automatically, one after the other: 8888 (display test); r and software
version number; 50H or 60H indication of the network frequency. Then the display switches to the
hour meter mode.
When the UV-C lamp is switched on for the first time, or after the reset function is used, the value
9,000 will appear on the display. A decimal point flashes beside the rightmost digit on the display
every second to indicate that the counter is running. The display is automatically set to the factory
hour meter reading of 9,000 hours. Up to 9,000 hours the UV-C lamp produces its rated radiation
level. After 9,000 hours the radiation diminishes. The radiation may then be insufficient to achieve
the desired results. If the UV-C lamp has been in use for some time and has been switched on
before, each time it is switched on the display will show the value it had before the UV-C lamp was
switched off. If the count of the hour meter is increased or decreased, the reading it had before the
display was switched off will be shown.
The hour meter settings can be changed if desired. This can be done as follows: After holding in the
switch (R) located below the display for 5 seconds, the display shows 'rSt' indicating that the user
menu has been selected. After releasing the switch (R) the counter and 'rSt' alternate on the display.
Now each brief press of the button will step through the menu options. There are three setting
options in the menu: 'rSt', 'up' and 'dn'.
UV-C and Pool equipment
UV-C and Pool equipment
SALTWATER TIMER UV-C |
9
EN