JUNO IC1RLWD REMODEL RECESSED HOUSINGS
WARNING: For your safety, read and understand instructions completely before starting installation.
Before wiring to power supply, turn off electricity at the fuse or circuit breaker box.
NOTE: Juno recessed fixtures are designed to meet the latest NEC requirements and are listed in full compliance
with the relevant UL standard(s). Before attempting installation of any recessed lighting fixture, check your local
electrical building code. This code sets the wiring standards and installation requirements for your locality and should
be understood before starting work. Use of non-Juno trims voids Juno warranty.
SAVE THESE INSTRUCTIONS
TYPE IC FOR
INSULATED CEILINGS
Figure 1
Juno Type IC fixtures are designed for direct
contact with insulating materials that are
approved for this application (Fig. 1). Fixtures
may also be used in non-insulated ceilings.
This Juno Air-Loc LED fixture is supplied
with means to seal the housing after installation
for energy savings and to comply with
energy code air leakage requirements per
ASTM E283.
INSTALLATION STEPS
Note: This housing is compatible with ceiling
thicknesses from 1/2" to 1-1/2" only.
Step 1. Remove optic assembly from carton
and store in a safe place for future installation.
Step 2. Locate center of proposed opening on
ceiling and use template to mark and
accurately cut a 4-3/8" opening (Fig. 2).
Figure 2
1300 South Wolf Road • Des Plaines, IL 60018 • Phone 800-323-5068 • www.junolightinggroup.com
INSTALLATION INSTRUCTIONS
Step 3. Follow steps 1-4 under Electrical
Connection.
Step 4. Press housing through ceiling opening
until flush to ceiling (Fig. 3). Push retention
clips outward until they click into position. Note:
To remove housing from ceiling, push tab on
clip upward to disengage.
Step 5. To seal housing after confirming
correct operation, apply supplied tape strips to
completely cover each of the three retention
clips and slots. Do not substitute with other
materials (Fig. 4).
Retention
Clips
Figure 3
Tape Strips to
Cover Springs
(3 Places)
Figure 4
FIxTURE DIMMING
IC1RLWD: 120VAC input housings. Dimmable
with most incandescent, magnetic low voltage,
or electronic low voltage* wall box dimmers.
Consult Juno Product Services or website
for compatibility.
*Electronic low voltage dimmers require a
neutral wire connection in the wall box
OPTIC ASSEMBLY
INSTALLATION
Step 1. After ceiling is finished and painted,
remove and discard paint shield from fixture.
Step 2. Locate the two large raised screws at the
top of the remodel housing. The optic assembly
uses these for retention.
Step 3. Insert optic assembly into housing,
with mounting feet aligned with raised screws.
Twist optic assembly clockwise so mounting feet
engage screws. Twist firmly to lock in place
(Fig. 7).
TRIM INSTALLATION
Insert trim into fixture by lining up trim springs
with the housing opening, and pressing trim up
towards the ceiling. Take note of the position of
the optic within the housing, and avoid contact
with it when pushing in trim.
© 2014 Juno Lighting LLC
Rev 5/14
P5943
pg 1 of 2

Publicidad

loading

Resumen de contenidos para JUNO IC1RLWD

  • Página 1 Before wiring to power supply, turn off electricity at the fuse or circuit breaker box. NOTE: Juno recessed fixtures are designed to meet the latest NEC requirements and are listed in full compliance with the relevant UL standard(s). Before attempting installation of any recessed lighting fixture, check your local electrical building code.
  • Página 2 Juno Lighting Group’s factory after prior written return authorization has been granted. This warranty shall not apply to products which have been altered or repaired outside of Juno Lighting Group’s factory. This warranty is in lieu of all other warranties, expressed or implied, and without limiting the generality of the foregoing phrase, excludes any implied warranty of merchantability.
  • Página 3 Antes de cablear a la fuente de energía, apague la electricidad en la caja de fusibles o cortacircuitos. NOTA: Los accesorios empotrados Juno están diseñados para cumplir con los últimos requisitos NEC y están enlistados en cumplimiento completo con los estándares UL pertinentes. Antes de intentar la instalación de cualquier accesorio luminoso empotrado, revise su código eléctrico de construcción local.
  • Página 4 Juno Lighting Group proporciona una garantía limitada de cinco años sobre los componentes LED a partir de la fecha de compra. La obligación de Juno Lighting Group está expresamente limitada a la reparación o reemplazo, sin cargo, en la fábrica de Juno Lighting Group después de que la autorización de retorno por escrito se haya otorgado.