JUNO FIREWALL
NEW CONSTRUCTION RECESSED HOUSINGS
WARNING: For your safety, read and understand instructions completely before starting installation.
Before wiring to power supply, turn off electricity at the fuse or circuit breaker box.
NOTE: Juno recessed fixtures are designed to meet the latest NEC requirements and are listed in full compliance with the
relevant UL standard(s). Before attempting installation of any recessed lighting fixture, check your local electrical building code.
This code sets the wiring standards and installation requirements for your locality and should be understood before starting
work. Use of non-Juno trims voids Juno warranty.
When installed according to the instructions provided and as specified in the UL Fire Resistance Directory, Juno IC1FW
LEDT24 luminaire may be used in fire resistance Floor-Ceiling and Roof-Ceiling designs. See UL Fire Classified Directories
CDHW and CDHW7.
NOTE: Use of Non-Juno trims voids Juno warranty.
SAVE THESE INSTRUCTIONS
TYPE IC FOR INSULATED CEILINGS
Figure 1
Juno Type IC fixtures are designed for direct contact
with insulating materials which are approved for this
application (Fig. 1). Fixtures may also be used in non-
insulated ceilings.
Juno Air-Loc LED housings are supplied with pre-
installed gaskets for energy savings and to comply
with energy code air leakage requirements per ASTM
E283.
INSTALLATION INTO JOIST
CONSTRUCTION
Figure 2
Step 1. Extend bar hangers to fit between joists.
Bar hanger foot is contoured to easily align with
bottom of joist (Fig. 2). Position fixture by
hammering Real-Nails
into joists (Fig. 3).
®
(Note: Bar hanger may be shortened to fit 12"
framing or smaller by breaking at score lines).
One Lithonia Way • Conyers GA 30010 • Phone 1-800-705-SERV (7378) • Visit us at www.acuitybrands.com/juno-recessed
©2020 Acuity Brands Lighting, Inc
INSTALLATION INSTRUCTIONS
FIRE RATED LED 4" IC1FW LEDT24
TM
Step 2. Slide fixture along bar hangers into desired location. Use locking screws or slot
to secure (Fig. 4).
Relocating Fixture – Nail can be removed with hammer claw to allow easy
repositioning of fixture without damaging bar hanger or nail (Fig. 5).
Step 3. Follow steps 1-4 under Electrical Connection.
Step 4. When installing in drywall, cut a hole measuring 4-1/2" diameter. After installing
drywall, adjust inner housing height (if necessary) to match the bottom surface of ceiling
by pulling down on inner housing, which is retained by springs. The housing is
adjustable for ceilings up to 1-1/2" thick.
Rev 06/20
P4747
Figure 3
Figure 5
Figure 4
1 of 2