Installation Instructions – Axcent (Small & Large)
5.
Hang the fixture by the quick-connect adapter onto
the pole arm. Tighten center Phillips head screw to 20
in-lbs. (Figure 13.)
6.
Make wiring connections inside the pole arm
compartment. Refer to wiring diagram for power
connections. (Figure 3.)
7 .
Install arm cover plate and tighten the (2) screws to 20
in-lbs (Figure 13). Ensure that the luminaire supply leads
are not pinched between the cover and mounting arm.
N
otee:
The quick connect arm adapter may not connect
perfectly flush, interference between the quick
connector arm is part of the design. Should be flush
within 1/16" .
6
EATON
IB514031EN
Installation instructions
1/16"
Align Cover Tabs
With Arm Slots
Figure 13.
Center Phillips Head
Screws and Tighten To
20In-Lbs. (2.3N-M)
Cover Plate Screws.
Tighten To 20 In-Lbs
(2.3N-M)