03220
REF.
INSTRUÇÕES IMPORTANTES DE SEGURANÇA / IMPORTANT SAFETY INSTRUCTIONS
CONNECTION
WARNING. DANGER OF DEATH THROUGH ELECTRIC SHOCK!
Must be installed by professional electrician.
- Disconnect power source.
- Cover or shied any adjacent live components.
- Ensure device cannot be switched on.
- Check power supply is disconnected
- Unload the faceplate of sensor and adjust the time and LUX knob.(refer to figure 1)
- Loosen the screw in the back and unload the bottom (refer to figure 1).
- Find the wire hole in the bottom and pass the power wire through hole. Connect the power wire into
connection-wire column according to the connection-wire diagram.
- Fix the bottom with inflated screw on the selected position. (refer to figure 2)
- Install back the sensor on the bottom, tighten the screw and then test it.
FIG. 1
CONNECTION-WIRE DIAGRAM (See the right figure)
TEST
- Set the function switch to "ON", set "TIME" anti-clockwise to minimum, "LUX" clockwise to maximum.
- Switch on the power, the lamp should be on.
- Set the function switch to "OFF", the lamp should be off immediately.
- Set the function switch to "PIR", Switch on the power; the sensor and its connected lamp will have no
signal at the beginning. After Warm-up 30sec, the sensor can start work .If the sensor receives the induction
signal, the lamp will turn on. While there is no another induction signal any more, the load should stop
working within 10sec±3sec and the lamp would turn off.
- Set "LUX" anti-clockwise to minimum, if the ambient light is more than 3LUX, the inductor load should not
work after the load stop working. If the ambient light is less than 3LUX (darkness), the sensor would work.
Under no induction signal condition, the load should stop working within 10sec±3sec.
Note: when testing in daylight, please turn LUX knob to
work! If the lamp is more than 60W, the distance between lamp and sensor should be 60cm at least.
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
FIG. 2
(SUN) position, otherwise the sensor lamp could not
-3-
FIG. 3