Elko EP SOU-1 Manual Del Propietário página 3

Ocultar thumbs Ver también para SOU-1:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 17
ELKO EP, s.r.o.
Palackého 493
769 01 Holešov, Všetuly
Czech Republic
Tel.: +420 573 514 211
e-mail: elko@elkoep.com
www.elkoep.com
Made in Czech Republic
02-68/2016 Rev.: 1
Characteristics
• Is used to control lights on the basis of ambient light intensity
• Used for switching street illumination and garden lights, illumination of
advertisements, shop windows, etc.
• Level of ambient intensity is monitored by an external sensor and output is
switched according to set level on the device
• Control input for additional control, e.g. time switch, preswitch etc.
• Level of illumination adjustable in two ranges:
- 1 - 100 Lx - device reacts to low intensity of surrounding illumination. It is for
twilight control.
- 100 - 50 000 Lx - device reacts in a wide range of illumination intensity. It is not
possible to set twilight sensitivity in this range but it is possible to operate
permanent illumination in rooms or to diff er sunny / cloudy. Applicable for
controlling of sunshades or controlling of circulating pump for heating by sunlight.
• Adjustable time delay to eliminate short term fl uctuation in illumination
• External sensor IP44 suitable for mounting on the wall (cover and holder of a
sensor are a part of the package)
• Supply voltage AC 230 V or AC/DC 12 - 240 V
• Output contact: 1x changeover / SPDT 16 A
• Red LED output indication
• 1-MODULE, DIN rail mounting
Description
1
2
3
4
cos φ ≥ 0.95
Type of load
AC1
Mat. contacts AgSnO
,
2
contact 16A
250V / 16A
Type of load
AC13
Mat. contacts AgSnO
,
2
contact 16A
x
1. Terminal of blocking input
5
6
2. Supply indication
3. Setting of level of illumination
7
4. Fine setting of level of illumination
8
5. Supply voltage terminals
6. Terminals for sensor
7. Output indication
9
8. Switch of test function TEST
9. Setting of output contact delay in range
of 0 - 2 min.
10. Output contact
10
M
M
AC2
AC3
250V / 5A
250V / 3A
K
AC14
AC15
250V / 6A
250V / 6A
SOU-1
Twilight switch
Symbol
Connection
Description of settings
a)
1
LUX
2
TEST
a) By switching to position TEST all function are switched off and switching contacts of
output relay are switched on. The function TEST is used for testing of right connection of
load and for verifi cation of failure (breaking of the bulb).
b) Range 1 - 100 Lx.
c) Range 100 - 50 000 Lx.
AC5a
AC5a
uncompensated
compensated
230V / 3A (690VA)
to max. input C=14uF
230V / 3A (690VA)
M
DC3
DC1
24V / 3A
24V / 10A
1 / 2
A1
16 18
IN
IN
S
A2
15
L
N
A1
S
A2
IN
IN
15 16 18
b)
1
LUX
2
TEST
HAL.230V
AC5b
AC6a
1000W
x
250V / 3A
M
DC5
DC12
24V / 2A
24V / 6A
EN
c)
1
LUX
2
TEST
AC7b
AC12
x
DC13
DC14
24V / 2A
x

Publicidad

Tabla de contenido
loading

Tabla de contenido