Descargar Imprimir esta página

DART Controls 13DVE Serie Manual De Instrucciones página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

MODEL 13DVE Rev.A / 15DVE Rev.A HOOK-UP
IMPROPER INSTALLATION OR OPERATION OF THIS CONTROL MAY RESULT IN INJURY TO PERSONNEL OR ELECTRONIC FAILURE. THE
CONTROL MUST BE INSTALLED AND GROUNDED IN ACCORDANCE WITH LOCAL, STATE, AND NATIONAL SAFETY CODES. AT NO TIME
SHOULD THE CIRCUIT CONTINUITY BE CHECKED BY SHORTING TERMINALS WITH A SCREWDRIVER OR OTHER METAL DEVICE.
1) Before attempting to wire the control, make sure all power is turned off.
2) Use a normal blow fuse, wired in series with all hot AC line inputs, rated to 125% of motor current. Note: Both
AC lines should be fused for 240 VAC input.
CAUTION SHOULD BE USED IN SELECTING THE SIZE OF HOOK-UP WIRING. LIMIT THE VOLTAGE DROP THROUGH THE WIRING TO 5% OF
THE LINE VOLTAGE AT FULL LOAD.
3) +ARM: Connect to plus (+) Armature wire on motor:
4) -ARM: Connect to minus (-) Armature wire on motor.
5) AC1 and AC2:
15DVA's - 120/240 VAC - Connect one of the incoming AC lines to AC1 and the other AC line to AC2
13DVA's - 12/24 VAC - Connect one of the incoming AC lines to AC1 and the other AC line to AC2
6) +FIELD: Do not use for permanent magnet motors. This supplies +Field voltage for a Shunt Wound Motor. For motors
with dual voltage field (ie; 50/100V or 100/200V), make sure the highest value is connected.
7) -FIELD: Connect to minus (-) Field wire of a Shunt Wound Motor.
CAUTION: DO NOT ATTEMPT TO PERFORM A HI-POT TEST ACROSS AC LINES WITH CONTROL IN CIRCUIT.
THIS WILL RESULT IN IMMEDIATE OR LONG TERM DAMAGE TO THE CONTROL.
1) Preset trimpots in the counter-clockwise (CCW) position.
2) Apply power and set the power on/off switch to the on position.
3) Rotate the Speedpot fully CW and adjust MAX trimpot in the CW direction until the maximum desired
speed is obtained.
4) Rotate the Speedpot fully counter-clockwise (CCW) and adjust the MIN trimpot in the CW
direction until deadband or the minimum desired speed is obtained.
5) The IR COMP trimpot is used as a regulation adjustment. If better motor regulation is needed between minimum and maximum loads, then adjust
IR COMP trimpot as follows. Rotate the Speedpot CW to the 50% position and rotate the IR COMP trimpot CW as needed to increase regulation.
6) Recheck and readjust trimpots if necessary. Trimpot interaction with each other will be minimal.
PLEASE READ COMPLETELY BEFORE MAKING ANY ADJUSTMENTS
HOOK-UP & TERMINAL IDENTIFICATION
15DVA's - 0-90 VDC for 120 VAC input, and 0-180 VDC for 240 VAC input.
13DVA's - 0-11 VDC for 12 VAC input, and 0-22 VDC for 24 VAC input
ADJUSTMENTS
WARNING
1

Publicidad

loading

Este manual también es adecuado para:

15dve serie