OPERATING AND MAINTENANCE MANUAL
SERIE VERTI
1. APPLICATIONS
1) It is applicable to main pipe pressurization. high-rise buildings pressurization.
high-rise buildings pressurization, pressure tank pressurization, sprinkling irrigation. trickling irriga-
tion. cooling system and industrial cleaning. etc.
2) Transfer clean water and other non-corrosive liquids with low viscosity; do
not transport inflammable, explosive, gasified liquids and liquids containing solid
particles or fibers.
2. MODEL DESCRIPTION
Liquid temperature: +4ºC - + 60ºC
Max. ambient temperature:+ 40ºC
Max. pressure: 15 bar
PH: 6.5 - 8.5
Altitude: < 1000 m
3. TECHNICAL DATA
1). When the lighter entire pump needs to be enhanced, the water pump can be transported by
manual.
2). When the heavier entire pump needs to be enhanced, the water pump must be lifted at pump
head with a steel tape or other smilar way.
Probleme
Insufficient
pressure
Motor works
intermittently or the
stator winding is
burned out
Leakage of
mechanical seal
Abnormal noise
from pump
www.proindecsa.com / proindecsa@proindecsa.com
Cause
The inlet pipeline is too
long or with too many
bends pipe diameter is not
selected as required.
The impeller is jammed or
under overload operation
for a long time .
Incorrect grounding.
broken cable or the
electric pump is hit by
lightning.
The mechanical seal is
worn and torn by impuri-
ties.
Noise from the bearing.
Impeller is jammed.
4
Solution
Apply the pipe with the stipu-
lated diameter and make the
inlet pipe short.
Clear sundries in the pump
chamber; operate the pump
under the rated flow as much
as possible.
Seek for the reason, and repla-
ce win dins coils.
Clear or replace the mechan-
cial seal.
Replace with the same type
bearing
Remove foreign materials.