on walls, since it can cause vibrations and noise. But, if it is the
only place available, follow these suggestions:
hand type or loafer, duly measured for your appliance, similar
dimensions to those for wall installation.
supporting it with rubber cradles to avoid vibrations and noise.
N

ELECTRICAL INSTALLATION

1. All the wiring will have to comply with the local and national codes of electricity and
it will have to be installed by qualified personnel.
2. There must be available an individual derived circuit with a proper outlet for the
exclusive operation of this air conditioning appliance. Consult following table with information
on the capacity suggested for the cables for the derived circuit.
3. It is essential that the outlet plug that you select matches the inlet plug of the
appliance and it is within reaching distance of the installed appliance.
NOTE: The inlet cord is 39 inches (991 mm) long and it is at-
tached to the lower part of the command checkerboard. DO NOT
USE a plug adapter nor an extension cord. Check Table 2 for in-
formation on types of plugs and fuses.
4. Comply with the fuse type (Table 2) indicated in the data plate of the appliance,
located above the air discharge.
5. IMPORTANT : The wires in the principal cable are arranged according to the following
colour code:
Green and Yellow: Earth
Since the colors of the wires in the principal cable of this equipment could not
correspond to the terminals identifying colours in the plug, proceed in the following way:

the green and yellow wire must be connected to the terminal in the plug that it is labeled
with the letter E (Earth) or by the earth symbol or coloured green and yellow.

the blue wire must be connected to the terminal that it is labeled with the letter N or black
coloured.
- You must have an iron or steel reinforced structure, French
- Avoid all contact of the appliance with the glass panes,
Blue: Neutral
7
Brown: Phase