AllPondSolutions AQUAFLO-PP RANGE Manual Del Usuario página 9

Filtro para estanque de frecuencia variable
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

TROUBLESHOOTING
The Pump is Noisy
If your pump is making excess noise, this is normally caused by the following:
1. Debris has collected inside the pump
2. The ceramic shaft is worn or broken
Remove your pump from your pond to clean / remove any debris
Ÿ
Inspect the ceramic shaft for any damage and replace if necessary.
Ÿ
Water Is Not Flowing Through The Pump
If water is not flowing through your pump correctly, this could be caused by:
1. Damage to the impeller
2. An inlet or outlet obstruction.
3. An obstruction in the filter basket.
4. Low voltage to the unit.
Clean and inspect the impeller (see maintenance section) and replace if
Ÿ
required.
Remove any blockages from the inlet/outlet and filter basket.
Ÿ
Check the voltage being supplied to your unit.
Ÿ
The Pump Is Not Running Correctly
If your pump will not run, this could be due to the following causes:
1. It is not connected to a power supply
2. The pump is not fully submersed and is being run dry.
3. The pump is not connected to the controller.
4. The controller is damaged
Check that the unit is correctly connected to the power supply and the RCD
Ÿ
unit is not faulty.
Ensure that the pump is fully submersed in your pond and filled with water.
Ÿ
Ensure that the controller is correctly connected to the pump. If it is
Ÿ
connected but still not working, contact the supplier of your unit for further
troubleshooting or replacement.

Publicidad

Tabla de contenido
loading

Tabla de contenido