IMPORTANT SAFETY RULES:

The present apparatus is a submersible filter pump for ornamental ponds and aquariums including a sterilizer using a UV-C lamp. The degree of protection
IPX8 identifies its use in immersion .. Any other type of use is not allowed and consequently it is not covered by the manufacturer's responsibility. NOTE:
BEFORE STARTING ANY OPERATION OF USE AND MAINTENANCE OF THE DEVICE, PLEASE READ THE MANUALS OF USE AND MAINTENANCE. THE MANUFACTU-
RER CANNOT BE HELD IN ANY CASE RESPONSIBLE OF ACCIDENTS OR DAMAGE RESULTING FROM INAPPROPRIATE USE OF THE DEVICE, AS WELL AS EVEN
PARTIAL FAILURE TO OBSERVE THE SAFETY REGULATIONS AND THE INTERVENTION PROCEDURES DESCRIBED IN THE MANUALS. ATTENTION: THE DEVICE
EQUIPMENT CAN BE PUT INTO OPERATION ONLY AFTER IT HAS BEEN CORRECTLY INSTALLED AND CONNECTED AND THAT THE USER HAS PREVIOUSLY READ
THE MANUAL.
CAUTION: This symbol on the product label and on its packaging indicates that this instruction manual must be read carefully before
the appliance is started up or serviced. be held responsible for any damage caused by this appliance if you have not read and understood this instruction
manual carefully or if you have not followed this.
In order to avoid any type of accident, carefully observe the following warnings (in addition to the most basic safety regulations). -This appliance can be
used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play
with the appliance. Cleaning and user maintenance shall not be made by children without supervision. - WARNING: Unplug or switch off all appliances in
the aquarium or pond before carrying out maintenance. If the connection plug of some appliance or the socket are wet, turn off the main switch before
disconnecting the power cord of the appliances present. - The supply cord cannot be replaced. If the cord is damaged the appliance should be scrapped. -
Check the voltage on the device label and ensure it corresponds to the main power supply.
- When the device is plugged to the mains, ensure that the lowest part of the lead is lower than the socket, to avoid any drops of water that are on the
lead flowing into the socket. If the cable is wet, do not touch the plug with your hands and before disconnecting the device, turn the mains switch off.
- We recommend that this device and other electrical aquarium devices should be connected to power supplies with ground fault circuit interrrupters lnd
30 mA. Outdoor use: don't bury the power supply cable, but follow the installation rules provided by the local regulations in force and please consult a
qualified electric installer. During installing the appliance or maintaining it, please don't lift it using the power cord. Before putting the appliance into
operation, make sure you have installed it correctly. Never carry out repairs or technical modifications to the appliance and use only original spare parts.
CAUTION: avoid direct exposure to sunlight. Do not use if there is a risk of freezing: in winter it is advisable to remove the appliance or operate it only if
it is protected against freezing. The appliance must only work in the presence of water and can not run dry. Do not use for drinking water. Do not use for
flammable or explosive, abrasive or corrosive liquindi. Use only for the treatment of pond or aquarium water. CAUTION: do not connect to the public water
supply (public aqueduct). WARNING: the appliance can be immersed in water up to the maximum depth indicated by the following symbol
on the
m
product label. Be sure to respect this warning. Preliminary checks
Checking for damage - Verify that the various parts of the device does not display physical damages due to bumps, tears or abrasions.
Check in particular:
• That there are no signs or dents, indicative of bumps caused by transport.
• The integrity of the the electrical cables.
Damage Reporting Procedure
If any damage is discovered, stop the connection procedure and report the nature of the damage to the Customer care office of the manufacturer.
KEEP THESE INSTRUCTIONS CAREFULLY!
WARNING: these devices contain an emitter of UV-C rays that can damage eyes and skin, improper use or damage to their protections and casings can
cause these radiation to escape, so if these devices are damaged they should not be used they must be discarded immediately.
-CAUTION: it is forbidden to use the UV-C lamp outside the appliance.
-WARNING: never look at the UV-C lamp when it is on.
-CAUTION: these devices contain glass. Handle with Care. INSTALLATION
Dear Customer, Thank you for purchasing AMTRA COMPACT SET 2000. With this practical and compact filter pump you will guarantee in your pond or
fountain a complete biological and mechanical filtration combined with UV-C water sterilization. You can also create water games or feed an external
filter (not included) or a waterfall. The pump must always work in immersion. Proceed with the installation of AMTRA COMPACT SET 2000 taking care to
choose a part of flat pond so that the pump can not accidentally fall. Decide on the water to be used and using the appropriate taps to adjust the water
flow of the respective outputs. The filter pump can also be used without water play by connecting only the pipe fitting to the water outlet. MAINTENANCE
When you notice a reduction in the flow of water you need to turn off the pump, remove it from the water after having previously turned off all other ap-
pliances, remove the pump and clean the sponge and impeller. The impeller must be carefully extracted from its housing and rinsed under running water
to remove residues of dirt or encrustations (in case of particularly persistent limescale deposits, it is recommended to leave the impeller in the vinegar
for 24h in a bath.In this case rinse thoroughly under water current before reassembling it). It is advisable to repeat this operation at least once a month.
Once cleaned, carefully reassemble each piece, reposition the pump according to the installation procedures and restart the appliance. UVC SYSTEM
GB
ISTR_COMPACT_2000.indd 10
04/01/19 16:42

Publicidad

Tabla de contenido
loading

Tabla de contenido