GZX This respirator meets the
requirements of EN 405:2001 + A1:2009 and should be
used to protect the wearer against certain gas / vapour
and particulate contaminants only.
^ Particular attention should be given to warning
statements where indicated.
^ WARNINGS
contaminants. Failure to follow all instructions on
Always be sure that the complete product is:
- Suitable for the application;
- Fitted correctly;
- Worn during all periods of exposure;
- Replaced when necessary.
refer to all information supplied or contact a safety
professional or 3M on 0870 60 800 60 (UK) or 1800 320
500 (Ireland).
USE LIMITATIONS
complete product in accordance with applicable Health
and Safety standards/guidance.
from natural rubber latex.
oxygen. (3M definition. Individual countries may apply
their own limits on oxygen deficiency. Seek advice if in
doubt).
atmospheric contaminants/concentrations which have
poor warning properties or are unknown or immediately
contaminants/concentrations which generate high heats
of reaction with chemical filters.
flames or liquid metal droplets.
resistance occurs.
c) You smell or taste contaminants or irritation occurs.
damaged or breathing resistance becomes excessive.
contact 3M Technical Service.

FITTING INSTRUCTIONS

^
Fitting Instructions must be followed each time the
product is worn.
1. Assemble/adjust head cradle by feeding the
perforated strip through the buckle and pressing down
on the stud at the required length. Repeat for the
second strip.
head harness over the crown of the head.
harness for a comfortable fit and repeat step 2.
the back of the neck and hook the straps together.
5. Tighten the top head harness first by pulling on the
ends of the straps to achieve a comfortable and secure
fit. Tighten the bottom straps in a similar manner. (Strap
tension may be decreased by pushing out on the back
of the buckles)
in place

FIT CHECK

7. Perform a Positive Pressure Fit Check.
Place palm of hand over exhalation valve cover and
exhale gently. If the face piece bulges slightly and no air
reposition the respirator on the face and / or re-adjust
the tension of the elastic strap and / or the head harness
to eliminate the leakage. Repeat the above fit check. If
be fit tested in accordance with national requirements.
contact 3M.

CLEANING AND DISINFECTION

If the respirator is to be used for more than one shift it
should be cleaned at the end of each shift and stored in
the original packaging or a sealed container.Use the 3M
™ 105 Face Seal Cleaner to clean the respirator.
moistened in warm soapy water (the water temperature
should be below 40°C) and dried at room temperature
in water.