• Use heater in accordance with all local codes.
• In the absence of local codes, refer to the National
Fuel Code, ANSI Z223.1.
• This heater is shipped from the factory for use with
propane (LP) gas only. Do not convert to any other
gas. Installation must conform to local codes or with
the standard for the Storage and Handling of Liquefied
Petroleum Gases ANSI/NFPA 58 and the Natural Gas
and Propane Installation Code CSA B149.1.
• Gas supply connections should be checked by
using a 50/50 soap and water solution. Never use a
flame to check for gas leaks.
• Locate LP cylinder at least 6 feet (10 ft. in Canada)
from the heater. Do not direct heater discharge
towards the LP cylinder unless it is at least 20 feet
from the heater.
1.
Remove all packing items applied to heater for
shipment. Keep plastic cover caps attached to inlet
connector and hose/regulator assembly for storage.
2. Remove all items from carton.
PAGE 3 OF 21
SAFETY WARNINGS CONTINUED
UNPACKING
SPECIFICATIONS
MODEL NO.
BTU
FUEL CONSUMPTION (LBS/HR)
MAXIMUM OPERATING HOURS
REQUIRED CYLINDER LBS
FUEL TYPE
HEATING AREA
AIR FLOW (CFM)
MAX. OUTLET TEMPERATURE
VOLTS (AC/Hz)
AMPS
• Use only the regulator and hose assembly provided
with this heater. Inspect the regulator/hose assembly
prior to each use of the heater. If there is excessive
abrasion or wear, or if the hose is cut, replace it with
the proper assembly shown in the parts list prior to
using the heater.
MINIMUM AND MAXIMUM INLET PRESSURE
Min.
Max.
WARNING! Risk of fire. Do not position heater in
a downward angle. Always position heater on a
stable and level surface. (See Figure 1)
3. Check all items for shipping damage. If the heater is
damaged, promptly inform Uline Customer Service.
CAUTION! The propane gas (LP) pressure
regulator and hose assembly supplied with the
heater must be used without alteration.
H-6511
H-6512
40k/50k/60,000
120k/135k/150,000
1.9/2.3/2.8
5.5/6.2/6.9
10.5
18
20
100
Propane
Propane
1,500 ft.
3,800 ft.
2
300
400
491°F
622°F
120V/60Hz
120V/60Hz
0.6A
0.8A
5 PSI
Bottle Pressure
2
0521 IH-6511
Figure 1