OBJ_BUCH-3069-001.book Page 28 Tuesday, April 18, 2017 2:39 PM
28 | English
Cause
"Wood" mode: Ring 7 lights up red even though there are no wooden beams in
the wall
Water-filled plastic pipe
Wall is not a dry wall
Inhomogeneous dry wall
Measuring tool placed onto
the wall very slowly
Uneven contact with the wall When taking measurements, always hold the measur-
Ambient temperature is too
high/too low
Severe temperature change Wait until the measuring tool acclimates to the ambi-
"Live" cable is not found.
No/atypical voltage on the
cable
Cable is located too deep.
Cable runs in grounded metal
pipe.
1 609 92A 3P0 | (18.4.17)
Corrective Measure
Water-filled plastic pipes in dry walls are also
detected in "Wood" mode.
"Wood" mode is only designed for dry walls.
Dry walls made from coarse chipboard can be highly
inhomogeneous and cause incorrect measurements.
For this reason, start the measurement at a different
place on the wall and measure at a different height. If
this does not help, hold an additional plasterboard
panel on the wall and perform the measurement on this.
Place the measuring tool onto the wall quickly.
ing tool so that contact with the wall is as even as pos-
sible and do not tilt the measuring tool.
Only use the measuring tool in an operating tempera-
ture range of –5 °C to +40 °C.
ent temperature.
Apply voltage to the cable, e.g. by turning on the cor-
responding light switches. It is not possible to reliably
detect multi-phase electricity cables and cables with
voltages outside the 110–240 V, 50–60 Hz range.
The scanning depth is dependent on the building
material and may be less than the maximum scanning
depth.
Select "Metal" mode to detect metal pipes.