Overall Dimensions; Firing Rate - Riello RG5DF Instrucciones De Instalación, Montaje Y Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2.3

OVERALL DIMENSIONS

247
12.5
36
D5390
2.4

FIRING RATE

Firing rate has been determined in conformity with the provision of standard EN 267 (from 3.1 to - 0.3 mbar).
In addition, burner can be applied for operation with the combustion chamber featuring negative pressure
(up to - 2 mbar) according to the approval terms provided for in standard EN 746-2 for the whole unit com-
plete with equipment.
3.0
2.0
1.0
0
-1.0
-2.0
8
D4444
100
2902
159
EN 267
EN 746-2
10
12
14
16
120
140
160
180
300
18
20
22
200
220
240
260
3
GB
213
127
160
190
24
26
Fuel output – kg/h
280
300
Thermal power – kW

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

398t13739870

Tabla de contenido