Installation Preparation; Mounting Plate Installation. Pgs - Litex Industries BNH44NI5C1S Guia De Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3. Installation Preparation.

To prevent personal injury and damage, ensure
that the hanging location allows the blades a
clearance of 7ft. (2.13m) from the floor and 30in.
(76cm) from any wall or obstruction.
This fan is suitable for room sizes up to 225
square feet (20.9 square meters).
This fan can be mounted only as a flushmount
on a regular ceiling. Downrod installations are
not available for this fan.
Installation requires these tools:
Phillips screwdriver, flat-head screwdriver,
adjustable pliers or wrench, stepladder, wire
cutters, and rated electrical tape.
4. Mounting Plate Installation.
Turn off circuit breakers to current fixture from
breaker panel and be sure operating light switch
is turned to the OFF position.
WARNING: Failure to disconnect power supply
prior to installation may result in serious injury.
Remove existing fixture.
WARNING: When using an existing outlet box, be
sure the outlet box is securely attached to the
building structure and can support the full weight
of the fan. Ensure outlet box is clearly marked
"Suitable for Fan Support." If not, it must be
replaced with an approved outlet box. Failure to do
so can result in serious injury.
CAUTION: Be sure outlet box is grounded properly
and that a ground wire (green or bare) is present.
Remove 4 motor mounting nuts and flat
washers from mounting plate--save for later use.
["Mounting Plate Installation" continued on
next page.]
blade edge
30
inches
7 feet
(2.13m) (76cm)
flushmount
installation
CANNOT be
installed on
angled or
vaulted ceilings
mounting plate
page 3
12 ft. - 15 ft.
(3.66m - 4.57m)
downrod
installation
motor
mounting
nuts
flat
washers