Installation Instructions – LXF/LXT
c.
Three-terminal block (3-wire service, 1 line,
1 neutral, 1 ground): Connect line service lead to
terminal that is connected to black factory-installed
wire. Connect neutral service wire to terminal that is
connected to white factory-installed wire. Connect
ground service wire to terminal that is connected to
green factory-installed wire.
d.
No terminal block (3-wire service, 2 lines, 1
ground): Connect 1-line service lead to black factory-
installed wire. Connect other line service lead to white
factory-installed wire. Connect ground service lead to
green factory-installed wire.
e.
No terminal block (3-wire service, 1 line, 1 neutral,
1 ground): Connect line service lead to black factory-
installed wire. Connect neutral service wire to white
factory-installed wire. Connect ground service wire
green factory-installed wire.
7 .
For fixtures with asymmetric light patterns, locate the
word "streetside" on the overhang plate and rotate the
fixture on the pole such that the word "streetside" is
facing the street.
8.
Secure the fixture to the pole top by tightening the
three-square head bolt using 9/16" socket and torque
wrench in the fixture base. Recommended tightening
torque: 120-140 in-lbs.
9.
Reattach bottom cover plate to fixture base and secure
with two cover retaining screws.
10. Replace the lens panels in right-side.
11. Close the cover carefully and secure with two cover
retaining screws or secure spring latches.
Caution: Carefully and slowly close the hinged top cover.
Always maintain contact and do not allow the hinged top
cover swing freely as it can fall or damage.
12. The fixture is now ready to energize.
Photocontrol Installation
Tools Required:
¼" Nut driver, #8 Flat head screwdriver.
When specified, the Lexington fixture is furnished with
a rotatable photocontrol receptacle that allows the
photocontrol to be properly positioned with the use of a
straight blade screwdriver.
1.
Remove three hex nut screws using ¼" nut driver and
lift off cupola. (Figure 3.)
2.
Remove the shorting cap (when furnished) and loosen
the two flat head screws.
4
COOPER LIGHTING SOLUTIONS
IB516007EN
Installation instructions
3.
Rotate the cupola until the window in the cupola is
facing in a northerly direction. (Figure 5.) Line up the
north arrow of the photocontrol receptacle with the
window in the cupola. Retighten the screws and install
the photocontrol.
Figure 5.
4.
Replace the cupola and tighten the cupola with three
screws.
CAUTION: The receptacle has a built-in stop which allows
350° rotation. Do not attempt to rotate beyond this stop as
you will damage the receptacle.
Cupola Window To
Face North