Model FB2LED
Fireball
LED Warning Light
®
UL and cUL Listed for Type 4X, IP66 environments.
IP69K compliant enclosure.
Installation and Maintenance Instructions
Limited
Warranty: This product's limited warranty can be found at www.fedsig.com/SSG-Warranty.
Safety Messages to Installers and Users
a licensed electrician and follow all safety instructions. Failure to do so may result in property
damage, serious injury, or death.
• Read and understand all instructions before installing or operating the equipment.
• To avoid electrical shock hazards, do not connect wires when power is applied.
• In order to be an effective warning device, this product produces bright light that can be
hazardous to your eyesight. The possibility exists that rapid flashing lights could induce
photosensitive epilepsy. Do not stare directly at the light.
An Overview of the FB2LED:
powered LED signal that can be programmed to produce
one of three light patterns: steady, 60 FPM, and 120
FPM (preset to 60 FPM). Unit is available in 12-24VDC
or 120-240VAC UL/cUL Listed. Type 4X, IP66 enclosure.
Electrical ratings: 0.48A - 0.24A (12-24VDC) or 0.03A
(120- 240VAC 50/60Hz). Suitable for indoor or outdoor
use. IP69K compliant. Certified operating temperature:
-40°F to 150°F (-40° to 66°C).
Unpacking the Device: After unpacking the device,
examine it for damage and verify parts. The unit comes with: (1) FB2LED assembled unit with flying
leads, (1) Panel mount gasket, and (3) No. 8 x 1/2" panel mounting tapping screws. If a part is
missing or appears damaged do not attempt to install. Contact Federal Signal Customer Support at
+1 708-587-3587 or iordersup@fedsig.com.
Mounting the Device: Model FB2LED comes standard to mount on a flat (horizontal or vertical)
surface or 1/2" NPT threaded pipe. Vertical wall (LWMB2) or corner (LCMB2) mounting accessories
are sold separately.
• Pipe Mounting – Model FB2LED can be pipe mounted on a 1/2" NPT pipe. Feed wires through
pipe and turn clockwise to tighten. Recommended tightening torque is 5-ft-lbs (6.8 N-m).
• Surface/Panel Mounting – Using provided gasket as a template, mark three mounting holes
and center hole for wiring. Drill or punch 0.188" (5.0mm) diameter holes for mounting and a
.88" (22.0mm) for wiring. Set base on gasket, feed wires through center hole, and attach to the
mounting surface using provided No. 8 tapping screws from the underside.
: This product should be installed to code by
FB2LED is a high-
4.10"/ 104 mm
18AWG
1/2" NPT Entry
Lead Wires
Impact Resistant
Fresnel Lens
LED PCBA
Die-cast
Metal Base

Publicidad

loading

Resumen de contenidos para Federal Signal Fireball FB2LED

  • Página 1 The unit comes with: (1) FB2LED assembled unit with flying leads, (1) Panel mount gasket, and (3) No. 8 x 1/2" panel mounting tapping screws. If a part is missing or appears damaged do not attempt to install. Contact Federal Signal Customer Support at +1 708-587-3587 or iordersup@fedsig.com.
  • Página 2: Electrical Connections

    Repair Service: A return authorization is required. Contact your Authorized Distributor or Federal Signal Customer Support at +1-708-534-4756 or iordersup@fedsig.com. Defective products under warranty will be repaired or replaced at Federal Signal’s discretion. Lamp failures excluded. Product Returns: Product returns require a return authorization from Federal Signal prior to returning the product.
  • Página 3: Luz De Advertencia Led Fireball

    Póngase en contacto con el Servicio de Atención al Cliente de Federal Signal al +1 708-587-3587 o escriba a iordersup@fedsig.com Montaje del dispositivo: El modelo FB2LED viene estándar para montar en una superficie plana (horizontal o vertical) o en un tubo NPT roscado de 1/2".
  • Página 4 Servicio de reparación: Se requiere una autorización de devolución. Póngase en contacto con su distribuidor autorizado o con el servicio de atención al cliente de Federal Signal al + 1-708-534-4756 o escriba a iordersup@fedsig.com. Los productos defectuosos bajo garantía serán reparados o reemplazados a criterio de Federal Signal.
  • Página 5 (1) joint pour montage sur panneau, et (3) vis autotaraudeuses n° 8 x 12,7 mm (1/2 po) pour montage sur panneau. Si une pièce est manquante ou semble endommagée, n’essayez pas d’installer l’appareil. Contactez l’assistance clientèle de Federal Signal au +1 708 587-3587 ou iordersup@fedsig.com.
  • Página 6 Service de réparation : Une autorisation de retour est nécessaire. Contactez votre distributeur agréé ou l’assistance clientèle de Federal Signal au +1 708 534-4756 ou iordersup@fedsig.com. Les produits défectueux sous garantie seront réparés ou remplacés à la discrétion de Federal Signal. Les pannes de lampes sont exclues.