Descargar Imprimir esta página

ABB AF190-30 Instrucciones De Empleo página 4

Publicidad

1SFC100008M0201
A1
A2
M 3,5
1 Nm -9Ib.in
Noti ce.
This product has been designed for environment A. Use of this product in environment B may cause unwanted electromagnetic disturbances
in which case the user may be required to take adequate mitigation measures.
Hinweis e.
Dies ist ein Produkt für Umgebung A. In Haushaltsumgebung kann dieses Gerät unerwünschte Funkstörungen verursachen; in diesem Fall kann
Noti ce.
Ce produit a été conçu pour environnement A. L'utilisation de ce produit dans environnement B peut causer des perturbations électro-
magnétiques non désirées qui, dans ce cas, peuvent obliger l'utilisateur à prendre des mesures d'atténuation appropriées.
Obs.
Den här produkten har konstruerats för miljöklass A. Användning av produkten i miljöklass B kan förorsaka oönskade elektromagnetiska
störningar och i så fall krävs att användaren vidtar nödvändiga åtgärder.
Avvertenza. Questo prodotto è stato progettato per l'ambiente A. L'uso di questo prodotto nell'ambiente B può provocare disturbi elettromagnetici
indesiderati, nel qual caso l'utilizzatore può dover prendere adeguate misure per loro attenuazione.
Nota.
Este producto ha sido diseñado para ambientes A. El uso de este producto en ambientes B puede causar perturbaciones electromagnéticas
no deseadas, en tal caso el usuario tendrá que tomar las medidas de mitigación adecuadas.
本产品适用于环境 A, 在环境 B 中使用本产品会产生有害电磁干扰, 在此情况下用户需采取适当防护措施.
警告!
.
According to UL 60947-4-1
Use wire Cu 75°C only.
AF(S)190, AF(S)205: Use Pressure Terminal Connectors ILSCO D-3608 (ABB ref. ATK185) or use Listed (ZMVV/7) Wire
Connectors and Soldering Lugs. Wire connectors (Cable pole-shoe) crimped with special factory crimp tool. Enclosure
with min. dimension 24 by 20 by 10 inches should be used. Suitable for use on a circuit capable of delivering not more
than the max. symmetrical amperes at the max. voltage shown in table 1 below.
AF(S)265, AF(S)305, AF(S)370: Use Pressure Terminal Connectors ILSCO D-3615 (ABB ref. ATK300/2) or use Listed (ZMVV/7)
Wire Connectors and Soldering Lugs. Wire connectors (Cable pole-shoe) crimped with special factory crimp tool. Enclosure
with min. dimension 36 by 30 by 12 inches should be used. Suitable for use on a circuit capable of delivering not more than
the max. symmetrical amperes at the max. voltage shown in table 2 below.
AF(S)190, AF(S)205
Circuit Breaker A
Fuse A/Class
Max Short Circuit Current at 208-240V (kA)
Max Short Circuit Current at 480V (kA)
Max Short Circuit Current at 600V (kA)
AF(S)265, AF(S)305, AF(S)370
Circuit Breaker A
Fuse A/Class
Max Short Circuit Current at 208-240V (kA)
Max Short Circuit Current at 480V (kA)
Max Short Circuit Current at 600V (kA)
Circuit Breaker A
Fuse A/Class
Max Short Circuit Current at 208-240V (kA)
Max Short Circuit Current at 480V (kA)
Max Short Circuit Current at 600V (kA)
ø 5,5
Pz 2
1 x 1 ... 4mm²
2 x 1 ... 4mm²
1 x AWG 18 ... 14
2 x AWG 18 ... 14
.
.
Table 1
T5*
400/RK5
10
10
10
Table 2
T5*, T6*
800L
10
18
18
Herm. ref. comp, AC-8a
TYPE
FLA
200
AF(S)190
AF(S)205
250
AF(S)265
300
AF(S)305
350
AF(S)370
520
1 x 0,75 ... 2,5mm²
1 x 0,75 ... 2,5mm²
2 x 0,75 ... 2,5mm²
2 x 0,75 ... 2,5mm²
1 x AWG 18 ... 14
2 x AWG 18 ... 14
T5N400
T5S400
400J
100
65
100
100
25
35
100
18
25
T5N600
T6S600
600J
100
65
100
100
35
50
100
20
25
T6N800
T6S800
65
100
35
50
20
25
Ballast, AC-5a/
Resistance air heating
LRA
1400
250
1500
300
2100
400
2450
450
3120
520
1 x 0,75 ... 2,5mm²
I > 3,5 mm
L < 8 mm
2 x 0,75 ... 2,5mm²
.
T5H400
T5L400
T5V400
100
100
100
65
100
100
35
65
100
T6H600
T6L600
T5V600
100
100
100
65
100
100
35
42
100
T6H800
T6L800
100
100
65
100
35
42
Elevator
duty
77
99
125
144
156
4/5
9 mm

Publicidad

loading

Este manual también es adecuado para:

Afs190b-30rtAf205-30Afs205b-30rtAf265-30Afs265b-30rtAf305-30 ... Mostrar todo