Bühler technologies BCM-MS Guía Rápida página 14

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 22
BCM-MS, BCM-LS
Measurements
outside the spe-
cification
• No analog
Cable not prop-
output
erly connected
Operating
voltage outside
the prescribed
range.
Interface config-
uration incorrect
Analog outputs
wired incorrectly
• No sensor
Cable not prop-
communic-
erly connected
ation via
CAN
Operating
voltage outside
the prescribed
range.
Interface config-
uration incorrect
CAN interface not
enabled
• Absolute
Calibrating para-
humidity
meter settings in-
measure-
correct
ment incor-
rect
Measuring range
setting incorrect
14
Bühler Technologies GmbH
expected with gearboxes
and unfavourable install-
ation positions.
Observe the technical
data and operate the
sensor within the spe-
cified measurement
ranges.
First check the electrical
connection of the sensor
and verify the data and
power cable are properly
connected. Please note the
prescribed pint assign-
ment.
Please operate the sensor
within a range between
9 V and 33 V DC.
Check and if necessary
correct the settings of the
analog outputs.
Observe the information
on measuring the analog
outputs
First check the electrical
connection of the sensor
and verify the data and
power cable are properly
connected. Please note the
prescribed pint assign-
ment.
Please operate the sensor
within a range between
9 V and 33 V DC.
Check and if necessary
correct the settings for the
interface parameters. The
correct setting depends
on the sensor configura-
tion.
enable the CAN interface
with the RS232 port, CM-
SensorConfig or a ter-
minal program as de-
scribed in chapter Opera-
tion and Control.
The calibrating paramet-
ers are specific to the oil
and must be pro-
grammed.
Please contact Bühler
Technologies GmbH Ser-
vice.
The measuring range is
specific to the oil and
must be programmed.
Tab. 6: Error: No sensor communication with HyperTerminal
Please contact Bühler
Technologies GmbH Ser-
vice.
BX150104 ◦ 03/2021

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bcm-ls

Tabla de contenido