Maintenance And Cleaning; Extraordinary Maintenance; Cleaning The Support Grid Of The Parts; General Cleaning Of The Machine - Elcometer SAGOLA AQUAPLASTIC+ Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Malfunction
The gun does not disburse
water/Brush does not
disburse water
The gun doesn't spray
water
The maintenance of the machine must be perfor-
med by qualified staff, according to the instructions
in this manual. Disconnect the pneumatic/electric
supply before performing any maintenance or
repair operations.
The adhesive warning, legal obligation and prohi-
bition labels and the installation plates on thema-
chine indicating the prohibitions and warnings are
MAINTENANCE OPERATION

Cleaning the support grid of the parts

Cleaning the entire machine
Cleaning the cigar-shaped filter
Replacing the fabric filter
Replacing the brush head

9.1. EXTRAORDINARY MAINTENANCE

Extraordinary maintenance operations should
only be performed by specialized staff: contact
the manufacturer for any extraordinary mainte-
nance required. Extraordinary maintenance
usually regards the breakage of machine compo-
nents.
9.2. CLEANING THE SUPPORT GRID OF THE
PARTS
Clean every day using the spray gun. If there are
patches of paint that are particularly difficult to
remove, use a spatula to scrape them off.

9.3. GENERAL CLEANING OF THE MACHINE

Every week give an overall clean to the machine,
using solvent and a brush or a spatula if especia-
lly stubborn layers of paint have deposited.
Periodically check that the safety devices are
functional and undamaged.
Any incrustations must be removed from the
drains and control valves regularly.
Cause
Obstruction of the aspiration tubes
The aspiration tube isn't inserted into the
collection tank
The collection tank is empty because the
fabric filter is blocked (it doesn't filter)
The air supply hose is disconnected
Lack of pneumatic supply

9. MAINTENANCE AND CLEANING

- 18 -
Remedy
Plug the end of the tube and make it do the
reverse air path
Insert the aspiration tube inside the lower
collection tank
Replace the fabric filter
Restore pneumatic supply
expressly indispensable. In the case of damage or
non-readability, the labels must be replaced imme-
diately.
It is absolutely forbidden to carry out operations
with the machine when not perfectly visible all the
labels or in the event of accidental were tampered
with by the location where they were previously
placed.
FREQUENCY
Every day
Every week
Every 2 week
Long filtration times*
4 - 6 Months
*Dependent upon type of washing

9.4. CLEANING SUCTION FILTERS

Every 2 weeks, clean the suction filter present on
the suction pipe of the machine then proceed as
follows:
• Unscrew the suction filter from the relative
pipes.
• Fully immerse the filter (soiled with paint) in a
basin full of solvent and leave to soak for 1 hour.
• After soaking for 1 hour, use the air gun to blow
the filter.
• Screw the suction filters onto the relative pipes.

9.5. REPLACING THE FILTER

Should filtering take a long time, open the lower
door of the machine and replace the nonwoven
fabric filter with another, new filter.

9.6. REPLACEMENT BRUSH HEAD

Every 4-6 months, verify the integrity of the brush
head and in case it occurs damaged and unusa-
ble, unscrew the head and replace it with a new
replacement of the same type.