SMART CHARGE IUoU Chargers
10
Trouble Shootings
After connecting and charging the battery, the battery voltage
would not increase.
If possible, measure with a suitable multimeter during the charging to
verify if the voltage at the battery terminals increases.
Determine whether the terminals are connected properly to the battery
poles. Clean the battery poles if necessary to ensure better connection.
After a charging time of approx. 20 hours, the battery is still
not fully charged
Disconnect the power to the IU0U automatic.
Remove the battery from the charging terminals and wait for a few
minutes.
Then, measure the voltage at the battery terminals with the multimeter.
If the multimeter displays a voltage of 10 V or less, this indicates that the
battery is defective and does not charge any longer.
The battery discharges after a short period of time without
usage.
Measure the voltage at the battery terminals with a suitable multimeter. If
the multimeter indicates a voltage below 12 V of a 12 V battery or a
voltage below 24 V of a 24 V battery, then the battery is too weak to retain
the charge.
19
SMART CHARGE IUoU Chargers
11
Specifications
Model Number:
Two plus 1A output for
Battery Connection
Input Voltage range
Charging end voltage
Economic charging voltage
Max. battery capacity
U0 phase limitation
Max. charging current
Operating temperature
Dimensions (mm)
Fuse:
Weight:
Protection
The following accessories are available for your IU0U automatic charger:
Remote control (Model number: 900-RC)
o
Temperature sensor (Model number: TF-500)
o
For any information, please contact your seller.
466095
466094
One plus 1A output
starter battery
for starter battery
207-253 V AC / 50 – 60Hz
14.4V/14.8V
13.8V
300Ah
150Ah
4 h or 8 h
25A
15A
0 ° C - 50 C°
240 X 77 x 310
200 x 60 x 260
T4 A / 250 V
T2A / 250V
3.5 kg
2,4kg
1.Short circuit protection
2.Overload protection
3.Reverse polarity protection
4.Overtemperature protection
20