Power Supply - Beurer IH 30 Manual

Ocultar thumbs Ver también para IH 30:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 18
• If you find that your Inhalator is not functioning correctly or is damaged, switch it off and dis-
connect it from the power line adapter or battery. Then contact your authorized dealer. Only
Beurer spare parts must be used.
The Inhalator consists only of parts that can be repaired or exchanged by the authorized dea-
ler/service agency.
• Batteries that are defective or no longer required should not be deposited in domestic waste.
Dispose of the fully discharged battery at disposal depots established for this purpose. You
can fully discharge the battery yourself by operating the Inhalator until its indicator lamp lights
red or flashes.

Power supply

The Inhalator can be operated in two different ways:
1. With the power line adapter
The power line adapter is suitable for use in homes provided with a 230V supply voltage. Insert the
small plug of the power line adapter into the socket underneath the Inhalator. Then plug the power
plug of the power line adapter into the socket outlet. The Inhalator is now ready to use.
2. With rechargeable battery
The battery allows you to use the Inhalator where no other power sources are available. Insert the
small battery plug into the socket underneath the Inhalator. Its operating time lasts up to 30 min.
If the indicator lamp lights red or flashes, this means that the battery is discharged and must be
charged up. Use only the rechargeable battery supplied by the manufacturer. The use of other bat-
teries can damage the Inhalator.
starting up
The Inhalator must be thoroughly cleaned before first use. This also applies if the Inhalator
has not been used for a long time (see "cleaning").
Filling the water tank
1. Connect the Inhalator to the power line adapter or the battery.
2. ensure that the Inhalator is switched off (the indicator lamp must
be not be lit, i.e. it must
neither flash green nor light up green!).
3. Remove the top cover from the Inhalator.
4. Fill the tank only with tap water or distilled water (20-30°C) otherwise you could damage your
Inhalator.
We recommend that you boil the water beforehand. The correct filling level is between the two
markings on the inside of the tank. If the water temperature is lower than 20°C, nebulization of
the medicament will be considerably less than at the specified temperature. The warmer the
water, the greater the degree of nebulization.
5. Empty the tank after every session and fill it again each time the Inhalator is used.
Filling the medicament cup
1. Place the medicament cup on the water tank.
2. Pour the medicament directly into the cup. Do not overfill the
medicament cup! The filling level is at max. 5 ml!
3. use medicaments only under your doctor's instructions and
check the inhalation time and quantity appropriate for you.
4. If the prescribed quantity of medicament is less than 2 ml, top it up to at least 4 ml with distilled
water or isotonic saline solution! Viscous medicaments must also be diluted. In this case also,
follow your doctor's instructions.
5. Replace the top cover back on the Inhalator again and ensure that it snaps into place.
4
10
max. 5ml
max. 5ml
app. 4ml
ca. 4ml
at least 2ml
mind. 2ml

Publicidad

Tabla de contenido
loading

Tabla de contenido