Button
Operating the device
Continuous lighting ON/OFF
• System can be switched ON or OFF, independently of motion or ambient brightness, for 12 hours max.
• NB: To prevent tampering, the continuous lighting OFF function is disabled in the factory settings. Activation
is only possible during the self-test. Switch the power supply on and press the
The continuous light OFF function is now enabled.
• To disable this function, press the
Operating continuous light mode ON/OFF
• Continuous light mode OFF disabled – Every time the button
• Continuous light OFF enabled – Pressing the button once switches the light ON for 12 hours. If the
is pressed again, the light will switch OFF for 12 hours. Press the
OFF – ON – OFF – ON.
• NOTE: After the maximum 12-hour „Permanent ON/OFF" period has expired, or if the
the detector will switch to Automatic mode.
"RELAY OFF" during the self-test
• For use on automatic stairwell lights in connection with impulse time setting.
• Switch the power supply on and press the (12h on/off) button during the self-test. The "RELAY ON" during the
self-test function is now disabled.
• To reactivate this function, press the (12h on/off) button during the self-test.
Storing the current light intensity value
• Stores the current light intensity value. To overwrite this value, turn the LUX switch or press the
Cancels the time settings / 12 hours ON/OFF
Reset
• Cancels the time settings. Exits continuous lighting ON/OFF.
Reset – During the self-test (after switching the power off).
• Resets the device to the default settings. Cancels all values set by remote control and resets all functions.
The device operates according to the preset factory settings (10 lux/2 min.).
NB: If the Continuous light OFF function is used further, it must be re-enabled.
button during the self-test. (Resets factory settings).
is pressed, the light switches ON for 12 hours.
button during the self-test.
button again to switch the light
button is pressed,
button again.
GB
button
13