1 • SAFETY INSTRUCTIONS
CAUTION: Work on the 230 V power system must be carried out
by authorised personnel only with due regard to the applicable
installation regulations. Switch off the power supply before
installing the system.
On the input side, the device is to be protected against short
circuits with a 10-A circuit breaker.
μ
= Contact gap < 1.2 mm
Use this product only as intended (as described in the user
instructions). Changes or modifications to the product or
painting it will result in loss of warranty. You should check the
device for damage immediately after unpacking it. If there is
any damage, you should not install the device under any
circumstances.
If you suspect that safe operation of the device cannot be
guaranteed, you should turn the device off immediately and
make sure that it cannot be operated unintentionally.
10
2 • DESCRIPTION
ESYLUX motion detectors are passive infrared detectors
which react to moving heat sources (e.g. people or vehicles)
(fig. 1 (1) head-on to detector (2) diagonally to detector). If
the motion detector senses a change in thermal radiation
inside its field of detection, depending on the set light value,
it will activate the connected system (e.g. an automatic
floodlight) for a preset length of time.
The ESYLUX MD-W200i motion detector features factory
settings and the detector operates according to preset values
(10 lux, 2 min.). The values can be individually modified. The
device can be preset using either the settings on the device
or, more conveniently, using the ESYLUX Mobil-RCi-M remote
control (available as an option).
3 • INSTALLATION/ASSEMBLY/CONNECTION
Before installing the device, observe the following:
• Turn off the power supply.
• Information concerning range is based on an installation
height of 2.50 m (the field of detection will vary
according to this height).
• For optimum performance (i.e. maximum range), position
the device so that people/vehicles are moving parallel to
the detector (fig. 1).
• Make sure that the detector has a clear line of sight, as
infrared beams cannot penetrate solid objects.