Nail 1/4" (6 mm)
thick furring strips
to the studs.
Stud
Use #6 large-head
galvanized nails to secure
the nailing-in flange to the
studs.
5. Secure the Whirlpool to the Stud Framing
Drill a small pilot hole through the nailing-in flange at each stud. Add shims between the nailing-in
flange and the studs as needed to eliminate gaps.
Nail 1/4" (6 mm) thick furring strips to the studs to shim out to the edge of the nailing-in flange.
Use #6 large-head galvanized nails to secure the nailing-in flange to the studs.
6. Cut the Pump Banding Straps
NOTE: If your pump model does not have banding straps, proceed to the next section.
IMPORTANT! This step is necessary to make your Kohler whirlpool operate more quietly.
NOTE: Do not raise the pump higher than it was before you cut the pump banding straps. If the pump is
raised too high, it will not prime properly.
Use tin snips to cut the two pump banding straps. When the banding straps are cut, the pump
support bracket and pump will drop about 1/2" (1.3 cm) until they rest on the subfloor. If the pump
drops more than 1/2" (1.3 cm), shim under the pump support bracket so there is a 1/2" (1.3 cm)
gap between the pump and bracket to allow for proper drainage.
To minimize whirlpool noise and vibration, be sure the pump is not in direct contact with the
shipping bracket after the pump banding straps are cut.
Secure the pump support bracket to the subfloor with screws or lag bolts (not provided).
7. Install the Plumbing
CAUTION: Risk of property damage. Ensure a watertight seal on the whirlpool drain.
Connect the drain to the trap according to the drain manufacturer's instructions.
Install the faucet valving according to the faucet manufacturer's instructions. Do not install the
faucet trim until instructed. Open the hot and cold water supplies, and check the supply
connections for leakage.
Run water into the whirlpool, and check the drain connections for leakage.
Kohler Co.
Drill a small hole
through the nailing-in
flange at each stud.
Drainage
NOTE: Pump model illustrated may differ from your
actual product.
9
Pump
Cut the pump
banding straps.
Suction Line
1011093-2-D