5.
Unused Battery Mode
The QC Test "Unused Battery" enables you to quickly
check new batteries in your inventory. The test can verify
up to 100 batteries in succession This test differs from
the Battery Test in that the decision is either pass or fail.
Neither decision will tell you that a battery is bad, but
rather that the measured voltage and CCA fall in or out of
your requirements.
1. Select UNUSED BAT. MODE from the Main Menu and
press E.
2. Select ON and press E.
3. The tester displays the total number of Inventory Tests
completed out of 100. Select Clear Memory to clear
the results from memory and reset the total to 0 or
select Add To Memory to add the results to memory.
!
Be sure to monitor the number of tests performed
and be ready to print the results as the number ap-
proaches 100. When the limit is reached you will no
longer be able to test until you clear all results from
memory.
4. Press E to continue.
5. APPLICATION
Scroll to and select AUTOMOTIVE, MOTORCYCLE, or
MARINE.
6. BATTERY TYPE
Scroll to and select STANDARD, AGM FLAT PLATE,
AGM SPIRAL, or GEL where applicable.
7. BATTERY STANDARD
Scroll to and select the battery's rating system. Not
all rating systems are available for each application.
Standard Description
CA
Cranking Amps
CCA
Cold Cranking Amps
MCA
Marine Cranking Amps
EN
Europa-Norm
EN2
Europa-Norm 2
DIN
Deutsche Industrie-Norm
SAE
Society of Automotive Engineers,
the European labeling of CCA
IEC
International Electrotechnical
Commission
JIS
Japanese Industrial Standard,
shown on a battery as a combinati-
on of numbers and letters.
Robert Bosch GmbH
8. BATTERY RATING
Scroll to and select the rating units. Hold down the
or to increase the scrolling speed.
9. VOLTAGE LIMIT
Scroll to select the voltage limit to be used for the
test.
10. Press E to start test. After several seconds the
tester displays the
dition and the measured voltage. The tester also
displays your selected battery rating and the rating
units.
Fig. 2:
i
Press to print the test results or to return to the
Menu.
Range
100-2000
100-2000
100-2000
100 – 2000
100 – 2000
100 – 1200
100 – 2000
100 – 1200
26A17 – 245H52
Unused Battery Mode | BAT 131 | 11
decision on the
Example of displayed results for a test of two batteries
1 689 989 132
en
battery's con-
|
2013-09-09