4.1.9. SELECT button: press SELECT button sequentially selects resistors, Continuity,
diodes, and capacitance measurement. In the continuity gears,this button use for
turning on/off indicator.
4.1.10. POWER button: Press this button 2 seconds to power on. After power on, press
the POWER button to cycle select the DC voltage, AC current, inrush current, AC
voltage measurement function.
4.1.11. "COM" common input jack.
4.1.12. Ω
4.1.13. Probe
4.2. Functional instructions
4.2.1. AC/DC Voltage Measurement
This meter will display AC current measurement function when power on, plug black
probe in "COM" jack, and plug red probe in "ACV/DCV" jack. When measuring the AC
voltage, connect the probe to the tested circuit to read the display readings. When
measuring the DC voltage, press POWER button switch to the DC voltage function, and
then connect the probe to the tested circuit to read the display readings.
NOTE:
1. DC voltage above DC50V or AC voltage above AC36V may cause electric shock
hazard and should be operation carefully in meausrment.
2.This instrument is not allowed to input voltages exceed 2000V. Be careful not to
insert the probe to "Ω
input jack.
" jact before measuring the voltage.
10