OWNER/INSTALLATION MANUAL
11�0 WARRANTY CONDITIONS
The following exclusions apply to the warranty given
by Dantherm Ltd. No claims will be accepted if:
1. The heat pump is installed in any way that is not in
accordance with the current procedures as defined
by Dantherm Ltd.
2. The heat pump has been worked upon or is
adjusted by anyone other than a person authorised
to do so by Dantherm Ltd.
3. The heat pump is incorrectly sized for the
application.
4. The water flow through the machine is outside the
specified limits.
5. The water pH level and/or chemical balance is
outside the following limits:
Acidity pH
Total Alkalinity, as CaCO3
Total Hardness, as CaCO3
Total Dissolved Solids
Maximum Salt Content
Free Chlorine Range
Free Chlorine Range
Superchlorination
Bromine
Baquacil
Ozone
Maximum Copper Content ppm
Aquamatic Ionic Purifier
6. The heat pump has suffered frost damage.
7. The electrical supply is insufficient or in any way
incorrect.
42
pH
7.2 - 7.8
ppm
80 - 120
ppm
150 - 250
ppm
1000
ppm
35000
ppm
1 - 2 Domestic
ppm
3 - 6 Commercial
max
30ppm for 24 hrs
ppm
2 - 5
ppm
25 - 50
ppm
0.9 Max
1
ppm
2 Max
8. The fan amps and duct pressure are outside the
specified limits.
9. The air flow to and from the machine is outside the
specified limits.
If in doubt or if advice is required please contact
the Dantherm Group UK Service Department by
calling +44 (0)1621 856 611 (option 4) or email
service�department@dantherm�com
Please give MODEL NUMBER and SERIAL NUMBER
of your heat pump when making technical or service
enquiries. This will assist in correct diagnosis and ensure
service can be provided with the minimum delay.
1005494 ISSUE 6