Optical Status Display, Maintenance - MH RWT35.50 Instrucciones De Operación

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Radio-wave Tool Setter RWT35.50
Optical Status Display
Maintenance
Service cover #3240
with O-Ring 16x1 Viton #3455
Metal eyelid
Conical spring
#2906
#2931
LED blinking green:
Tool Setter transmitting signal
LED blinking green / red:
Low Battery
LED blinking orange:
Stylus deflected
Dirt can build up under the metal eyelid!
To Clean:
Remove the service cover, metal eyelid, and
conical spring by hand.
Clean the Tool Setter and parts
with flowing water.
Reassemble and close by hand.
Align the measuring surface.
Calibrate Tool Setter!
Attention!
Do not use compressed air or pressure washer
to clean!
Do not use sharp objects as these can damage
the seals!