Descargar Imprimir esta página

Faber MatriX 450/500 Manual Del Usuario página 13

Ocultar thumbs Ver también para MatriX 450/500:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

7.6
ECO function and ECO+ function
ECO position 1 30% Up to 21°C
ECO position 2 40% Up to 22°C
ECO position 3 50% Up to 23°C
ECO position 4 60% Up to 24°C
ECO position 5 70% Up to max room temp setting
7.7
Thermostat function (place remote control in the
wall bracket)
The remote control has a built-in sensor to measure the room
temperature and should therefore be placed in the wall bracket. The
I.T.C. PID controller will automatically adjust the room temperature
to the selected value. The I.T.C. also uses the step function in
thermostat operation.
Smartphone/tablet
Follow the symbols and the instructions on the App to set the
required temperature.
Remote control
Use the key combination 1+4
Please note: the device regulates the temperature according to the
last setting on the App. You cannot adjust this choice using the
remote control.
8 Replacing the batteries in the
remote control
Remove the lid from the back of the remote control (fig. 1.3)
Fit 2x AA 1.5 Volt Alkaline long-life batteries.
Close the lid.
9 Explanation indication signals
on the remote
1x green: Command sent successfully from the remote.
1x red:
Command sent but no confirmation that the command
was received.
5x green: Remote control handset has successfully linked with
communication controller.
5x orange: Warning which requires attention, this could for
example be one or more of the following reports:
1.
Room temperature too high (as measured by the
remote control).
Communication controller temperature too high
(measured under the fire by the communication
controller)
2.
I.T.C. temperature too high (measured under the
appliance in communication controller)
3.
Maintenance is due
5x red:
Error situation, e.g.
1.
Hardware error
2.
Thermocouple gives a abnormal value
3.
Etc.
10 Explanation of notification signals
on I.T.C. LED
5x with interval of 30 seconds, green: I.T.C. linked to the Wi-Fi
network.
5x per second, green: Pair mode (connecting remote) active.
5x per second, orange: Access point mode.
1x per second, red: No connection via Wi-Fi.
11 Warning codes (visible in App.)
W_F15:
Temperature I.T.C. controller too high.
W_F14:
Room temperature is above the set temperature.
W_F13:
No recent room temperature received from remote.
W_F12:
System needs maintenance.
W_F11:
Remote has low battery.
W_F10:
Low voltage (mV) thermocouple.
12 Error codes (visible in App.)
E_F15:
Internal controller error.
E_F14:
Receiver needs to be reset.
E_F13:
Communication problems with receiver.
E_F12:
Voltage (mV) thermocouple too high.
E_F11:
System temporarily blocked by too many consecutive
alarms.
1 3
E N G
- U s e r m a n u a l

Publicidad

loading