Factory setting is Clean: On
Factory setting can be modified by pressing +
Modifying the factory setting is not recommended
Factory setting for rinsing duration: 4 minutes
Confirm with MENU / OK
5.1.3 Setting the mix water hardness
It is recommended to set a residual water hardness of
at least 8°dH to avoid corrosion damages.
It is recommended to check the output water hardness
regularly (2 times a year).
1.
Setting the mix water hardness by turning the screw at
the base of the diluting device
• Use screwdriver
• Turn counter-clockwise = increase water hardness
on output side
• Turn clockwise = decrease water hardness on
output side
2.
Check the mix water hardness at a tapping point
• Open tapping point completely to ensure sufficient
flow
3.
Readjust by turning the screw if necessary
• Hex allen wrench needed - M4mm
5.1.4 First Regeneration
1.
Start regeneration
• Press the Regeneration key for 5 seconds
• Display Regeneration active flashes
• The time is displayed in the display during the
regeneration process
2.
After the end of the regeneration
• Display Regeneration active goes out.
• The time is displayed
MU1H-1417GE23 R0420
GB
3.
The device is ready for operation
and -
6

Operation

+
-
6.1 Changing time raw water hardness
and residual
1.
MENU / OK
• Display Current time flashes
2.
Continue with point 2 to 7 chapter 6.2 Initiating a
manual regeneration
No regeneration needs to be carried out.
6.2 Initiating a manual regeneration
It is possible to initiate a manual regeneration (within
the 4-day interval). The manual regeneration is
carried out immediately.
1.
Press the REGENERATION key for 5 seconds
• Display Regeneration active flashes
• After completion of the regeneration, the device
returns automatically to the normal operating
mode
If the water was switched off for a longer period (more
than 4 days), it is recommended to carry out a manual
regeneration after re-establishing the water supply.
6.3 Refilling salt tablets
Check the salt supply (e.g. monthly) in the device
CAUTION!
Use only salt tablets acc. DIN 19604.
1.
Open the salt container cover
2.
Refill salt

6.4 Further information

6.4.1 Power Failure
Brief power failure:
All settings including the time remain intact
After longer power outage:
Display Current time flashes
Continue with point 2 to 11 chapter 10.2
The settings, excluding the time remain intact, but
need to be confirmed with MENU / OK.