TABLE I - Sta-Rite valves for
use with Model S7MD60
and S7MD72 filters
Port
Part
Size
Number
Multi-port
2"
18201-0300
Plastic Slide
2"
14935-0300
NOTICE: Use of valves
other than those listed
above could cause
reversed water flow
through filters and
damage to internal fil-
ter components.
INSTALLATION
Installation of filter should only be done by qualified, licensed personnel.
Filter mount must:
• Provide weather and freezing protection.
• Provide space and lighting for easy access for routine maintenance. (See
Figure 1 and Table II, Page 6, for space requirements.)
• Be on a reasonably level surface and provide adequate drainage.
• Be as close to pool as possible to reduce line loss from pipe friction.
Piping:
• Piping must conform to local/state plumbing and sanitary codes.
• Use Teflon tape or Plasto-Joint Stik' on all male connections of plastic pipe and
fittings. DO NOT use pipe compounds on plastic pipe; it will cause the pipe to
crack. Do not use sealant on unions—assemble them dry and hand tight.
• Support pipe independently to prevent strains on filter or valve.
• Use 2" (51mm) pipe to reduce pressure losses as much as possible.
NOTICE: Filter may be located away from pool, but for adequate flow larger
pipe may be needed. Check local codes for remote installation.
• Fittings restrict flow; for best efficiency use fewest possible fittings.
• Keep piping tight and free of leaks: pump suction line leaks may cause
trapped air in filter tank or loss of prime at pump; pump discharge line leaks
may show up as dampness or jets of water.
• NOTICE: Overtightening can crack filter ports.
Valves:
• A check valve installed ahead of filter inlet will prevent contaminants from
draining back into pool.
• A check valve installed between filter and heater will prevent hot water
from backing up into filter and deforming internal components.
• For installation allowing backwashing, install Sta-Rite Two Position Slide
Valve or Multiport Selector Valve with filter. See Table I. If you intend to
clean your filter according to "Module Cleaning Procedure", Page 10, no
slide or multi-port valve is required. See Figures 1 and 2, Page 6, for correct
water flow when connecting pipe.
• Filter ports and valve ports are furnished with union connections.
DO NOT use pipe sealants on union collar (nut).
• Use care before assembly not to damage union sealing surfaces or O-Ring.
• To allow recirculation during precoat (if precoat pot is used), install a recir-
culation line with shut-off between pad return line and pump suction.
Electrical
• All wiring, grounding and bonding of associated equipment must meet local
and/or National Electrical Code standards.