Displaying Special Statuses
The corresponding heater display alternates between two characters depending on the status.
Heater
Event
status
Heater with residual
Off
heat
Heater without pan
On
Induction generator
Off
over temperature
On
Induction generator
over temperature
Errors/Alarms
The corresponding heater display alternates between two characters depending on the Error.
Event
(Visualization Priority Order)
FalloKeyOnOffEmitter
FalloKeyOnOffReceiver
FalloNtcShort
FalloNtcOpen
FalloOverTemp
FalloEepromChecksum
FalloAdc
FalloSw
FalloAmbientLight
FalloDivisor
FalloTestLedOnOff
FalloTetGroupSelection
(*) All heaters switched Off and locked
Event
(Visualization Priority Order)
FalloComunicaciones
FalloNtcFocoShort
FalloNtcFocoOpen
FalloNtcFoco
FalloNtcGeneradorShort
FalloNtcGeneradorOpen
FalloNtcGenerador
FalloNoRedGenerador
FalloOverLoadGenerador
(**) Heater switched off and locked
(***) Generator Heaters switched off and locked
Start
conditions
Heater
Heater
Temperature > 50ºC
Temperature < 40ºC
No pan or not suitable
Heater Off
pan over the heater
Heat sink
Heat sink
Temperature > 90ºC
Temperature < 80ºC
APPLIANCE ERRORS
Description
Security Key Error
Security Key Error
Touch NTc Error
Touch NTc Error
Touch NTc Error
Eeprom Checksum Error
Security Key Error
Software Error
Keyboard Error
Security Key Error
OnOff Led Error
Keyboard Error
HEATER ERRORS
Description
Communication Error
Induction Heater Ntc Error
Induction Heater Ntc Error
Induction Heater Ntc Error
Induction Ntc Error
Induction Ntc Error
Induction Ntc Error
Induction Error
Induction Error
End
Action
conditions
----------
In 1 minute
Heater off
----------
No power is
delivered to
the heater
Action
App Off (*)
----------
App Off (*)
----------
App Off (*)
----------
App Off (*)
----------
App Off (*)
T < 90ºC
App Off (*)
----------
App Off (*)
----------
App Off (*)
----------
App Off (*)
Light Condition
App Off (*)
----------
App Off (*)
----------
App Off (*)
----------
Action
Induction Heaters Off(**) Comm. OK
Heater Off(**)
Heater Off(**)
Heater Off(**)
Generator Off (***)
Generator Off (***)
Generator Off (***)
Generator Off (***)
Generator Off (***)
40
Heater
Heater
Display fore
Display back
(1 sec.)
(1 sec.)
'H'
'H'
'Power'
'υ'
' ' or 'H'
'c'
'Power'
All Heater Displays
End
(fore 0.5 sec./ back 0.5 sec)
Heater Display
End
(fore 0.5 sec./ back 0.5 sec)
Serial Comm.
Serial Comm.
Serial Comm.
Serial Comm.
Serial Comm.
Serial Comm.
Serial Comm.
Serial Comm.
3PCLIOBIM64CGG
Priority
3
1
2
FA
FC
FE
FP
Fc
FH
FJ
F0
FL
FU
Fd
Fb
F5
F1
F2
F7
F3
F4
F8
F6
F9
06 luglio 2020