Troubleshooting - GYS CONVERGYS Serie Manual De Instruccion

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATION
150W MODEL:
1) Plug the CONVERGYS into the cigarette lighter.
2) Switch the inverter ON
3) Connect the desired equipment to the inverter (230V socket or USB 5V).
4) After use, unplug your equipment and then switch OFF the Convergys and disconnect it from the cigarette lighter.
* For changing the fuse contact a professional.
300W MODEL:
1) Choose desired connection:
• Directly onto battery: powers any device up to 300W.
• Cigarette lighter: powers any device up to 150W.
2) Connection:
Connect the red clip to the red "+" terminal of the converter and the black clip to the black "-" terminal of the converter; screw
clips in place.
Caution: reversing the polarity may damage the converter.
3) Connect the converter:
• Wire: Connect the black clamp to the negative "-" terminal of the battery and then connect the red clamp to the positive "+"
terminal of the battery
Caution: If the clamps are not connected securely there is a risk of low/no power, cable overheating, damage to the inverter
supply, or fire.
• Cigarette lighter: Connect the cigarette lighter plug into the socket.
4) Switch the inverter ON (the green LED illuminates) and connect your equipment to the converter. (230V or USB 5V)
5) After use, unplug your equipment and then switch OFF the Convergys and disconnect it from the cigarette lighter or the
battery.

TROUBLESHOOTING

SYMPTOM
No voltage output
The device turns ON and OFF intermittently The direct load is too high.
The inverter turns OFF when a connected
device is switched ON
FOR 150W MODEL
Output voltage too low.
FOR 300W MODEL
Warning Buzzer sounds
Red LED illuminates
The Convergys doesn't supply any voltage
Warning Buzzer sounds + red LED
illuminates
The Convergys doesn't supply any voltage
NB: The USB socket should continue to operate.
CAUSES
Bad connection
Weak battery
Thermal overload
Fuse failure (in the inverter or
vehicle)
The starting current is too high.
The battery voltage is below 10,2-
10,8V.
Input current below the required
level (10.2-10.8V)
Input current is below the
protection level (9.2-9.8V)
Input voltage exceeds the
protection level (15-16V)
Excessive load, the protection is
activated.
The temperature is too high.
REMEDIES
Check the cigarette lighter plug and cable connections
Check the vehicle battery
Start the engine of the vehicle if necessary
Stop the device. Leave the inverter to cool ensuring
adequate ventilation.
Check and replace fuse
Reduce the load
Check if the maximum power of the inverter is suitable for
the required power of the device
Charge or replace the battery.
The unit will start again when the battery voltage reaches
the operating level of the inverter.
The unit will start again when the battery voltage drops to
the operating level of the inverter.
Reduce the charge to the power level of the converter
The inverter will start again as soon as it has cooled down.
6