Enlaces rápidos

340868_Recessed TV Box IS:340868_RevB_RecesseVBox_IS
FRAME MOUNTING INSTRUCTIONS:
Note: Unit to be installed on finished wall, with a thickness of 1/8" to 1-1/16". Be sure
there are no obstructions behind wall surface, such as wall studs.
1) Place Frame facing wall in desired location and mark wall
through slots provided. Make sure there are no obstructions
behind wall before cutting.
2) Connect the marks and cut out wall surface. Cut Out
Dimensions: TV1W: 4-1/8" x 6-3/8" TV3W: 7-3/4" x 6-3/8"
3) Place Frame into cutout. Turn screws clockwise. Tighten until
snug against wall.
4) Insert P&S Signature™ end-cap tabs and firmly push to snap on.
Note: To remove Signature™ end-caps, insert small flat
screw driver into each notch and gently pry off. See figure 1.
TV3W
A) Line Voltage or Low Voltage Mounting Capable. Use
appropriate installation instruction.
B) Low Voltage Only. Use keystone jacks for hard wired
terminations.
www.passandseymour.com (full line of keystone jack options.)
LINE VOLTAGE INSTALLATION:
Warning – To prevent severe shock or electrocution, always turn power OFF at the
service panel before installing this unit, working on the circuit, or changing a lamp.
1) A P&S old work electrical box must be used. P116W, S116W & S118W are recom -
mended for best fit. Check for clearances before installation to ensure proper fit.
Center opening on TV3W may not be suitable for line voltage in all applications. (2x4
wall construction)
2) Pull cable through desired opening. Insert nonmetallic cable into Auto/Clamp
entry in the old work box.
3) Pull cable through to the desired length. Install UL listed Electrical devices per manu -
facturer's instructions.
2/14/08
Recessed TV Box
Installation Instructions
TV1W
11:47 AM
Page 2
P/N 340868 Rev. B
Fig. 1
®
cable

Publicidad

loading

Resumen de contenidos para LEGRAND pass & seymour TV1WTVSSW

  • Página 1 340868_Recessed TV Box IS:340868_RevB_RecesseVBox_IS 2/14/08 11:47 AM Page 2 Recessed TV Box Installation Instructions P/N 340868 Rev. B FRAME MOUNTING INSTRUCTIONS: Note: Unit to be installed on finished wall, with a thickness of 1/8" to 1-1/16". Be sure there are no obstructions behind wall surface, such as wall studs. 1) Place Frame facing wall in desired location and mark wall through slots provided.
  • Página 2 340868_Recessed TV Box IS:340868_RevB_RecesseVBox_IS 2/14/08 11:47 AM Page 3 4) Insert electrical box into Frame opening with the swing brackets flat to the box and turn screws clockwise until snug to Frame. 5) Use UL listed wall plates to complete the installation. Note: Max wall plate dimen - sions: 4-7/8"...
  • Página 3 340868_Recessed TV Box IS:340868_RevB_RecesseVBox_IS 2/14/08 11:47 AM Page 4 INSTALLATION POUR BASSE TENSION Attention – Pour éviter tout choc électrique ou une électrocution, toujours couper l'électricité au niveau du panneau d'alimentation avant d’installer cette unité, de travailler sur le circuit électrique ou de changer une lampe. 1) Utiliser l’ancienne boîte de jonction P&S.
  • Página 4 340868_Recessed TV Box IS:340868_RevB_RecesseVBox_IS 2/14/08 11:47 AM Page 1 A. Apto para montajes de voltaje de línea o bajo voltaje. Utilice la instrucción de instalación apropiada. B. Únicamente bajo voltaje. Utilice conectores Keystone para los bornes conectados por cable. www.passandseymour.com (gama completa de opciones de conectores Keystone) INSTALACIÓN PARA VOLTAJE DE LÍNEA: Advertencia –...