1. WHERE TO POSITION (Fig. 1.)
Excess moisture will travel throughout your home, in the same
way that cooking smells waft to every room in the house. For this
reason, the dehumidifier should be positioned, so that it can draw
this moist air towards it from all over the home.
Alternatively, if you have a serious problem in one area you can
begin by positioning the dehumidifier close to this area and later
moving it to a more central point. When positioning the
dehumidifier, ensure that it is placed on a level surface and that
there is a minimum of 10 cm (4") of space on either side of the
unit to allow for efficient airflow. This dehumidifier is fitted with
castors for extra mobility, if you move the unit, it should first be
switched off and the water tank emptied. We do not recommend
the use of an extension lead, so please try to ensure that the unit
is sufficiently close to a fixed mains socket. If it is necessary to
use am extension lead, please ensure the diameter of the wires
of the cable is at least 1 mm
operation, outside doors and windows should be closed when
necessary for most efficient use.
2. BEFORE USE
Caution!
• Always keep the unit in vertical position.
• Leave the unit to stand for one hour before connecting to the
mains supply after transport or when it has been tilted (e.g.
during cleaning).
• Keep all foreign objects away from the air intake or output
openings.
• The mains supply must conform to the specification shown on
the rating plate at the back of the unit.
• If the supply cord is damaged, it must be replaced by an
approved service representative or a similar qualified person
in order to avoid a hazard.
• Never use the plug to start and stop the unit. Always use
switch on the control panel.
• Before moving the unit, first switch off, then unplug and empty
the water tank.
• Don't use bug sprays or other flammable cleaners on the unit.
• Never pour or spray water over the unit.
• THIS APPLIANCE IS NOT INTENDED FOR USE BY
PERSONS (INCLUDING CHILDREN) WITH REDUCED
PHYSICAL , SENSORY OR MENTAL CAPABILITIES, OR
LACK OF EXPERIENCE AND KNOWLEDGE , UNLESS
THEY
HAVE
BEEN
INSTRUCTION CONCERNING USE OF THE APPLIANCE
BY A PERSON RESPONSIBLE FOR THEIR SAFETY.
CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT
THEY DO NOT PLAY WITH APPLIANCE.
IMPORTANT!
Do not use this unit at ambient temperatures below 5ºC, to
prevent the possibility of a heavily ice up evaporating coil.
3. PARTS (Fig. 2.)
1. Front Plate
2. Control Panel
3. Air Outlet
4. Handle for the unit
5. Rear plate
4. OPERATION (Fig. 3.)
1. Humidity selection button
2. Speed (ventilation) button
3. Display window
4. Temperature display button
5. ON/OFF button
6. Humidity indicator
7. High speed indicator
1. Plug the unit into a correct mains socket. (Please refer to the
rating
label
at
the
voltage/frequency.)
2. Press button ON/OFF to turn on the unit. The compressor will
start to work in continuous mode. (Ionizer (optional) will start
running automatically.)
3. Press button HUMI to set the room humidity you need:
continuous de-humidifying , 40%, 50%, 60% or 70%. (When
the room humidity is under 35%, the display will show 'LO'
and if the room humidity is over 95%, it will show 'HI'.)
2
. When the dehumidifier is in
GIVEN
SUPERVISION
6. Power cable
7. Filter inlet
8. Drain hole for continuous drainage
9. Water tank
10. Castors
8.
Low speed indicator
9.
Timer
10.
Water full indicator
11.
ON/OFF indicator
12.
TiO2 indicator
13.
TiO2 button (optional)
rear
of
the
unit
for
4. Press the speed button to choose the ventilation speed, high
or low.
5. Press
the
temperature. It will revert to display the room humidity after 12
seconds.
6. Press the timer button to set up the time for turn on/turn off
(1~24hr). The unit will be continuous de-humidifying without
timer setting.
7. Press TiO2 button to start the TiO2. (Optional)
8. To turn off the unit, press button ON/OFF again.
5. DRAINAGE
While the water tank is full, the compressor will stop for self-
protection and the water full indicator will turn into red.
The water full indicator
The unit will buzz. * For stopping the buzz, you may press the
ON/OFF button to turn off the unit
To move the water tank, pull it out squarely from the unit by using
the handle at the water tank (Fig. 4.).
After empting the water tank, place the water tank into space.
Make sure it is properly positioned, in order for the 'water full' sign
to go out and your dehumidifier is operating.
As the water tank is full or has not been positioned well, the water
level window will turn into red (Fig. 5.).
Please note, in case, the water tank has not been positioned well,
the water full indicator will turn into red.
Continuous drainage (Fig. 6.)
When the dehumidifier is operated at very high humidity levels,
the water tank will require more frequent drainage. In this
situation, it may be more convenient to set the unit up for
continuous drainage with the following procedures:
1. Connect the drain hole with a water tube of inner diameter
12mm. * Please note the water tube is not supplied with the
unit.
2. Ensure the water will always drain away freely and the tube
will remain in right place.
* Note! In very cold weather conditions, precautions should be
taken to prevent the water tube from freeing.
6. MAINTENANCE
Always unplug the unit from the mains before carrying out any
maintenance or cleaning of the unit.
CLEANING THE BODY
Use soft cloth to wipe the unit clean.
Don't
ever
OR
chemically treated clothes, or other cleansing solutions. These all
could possibly hurt the cabinet.
CLEANING THE AIR FILTER
• Remove the filter from the unit back. (Fig. 7)
• For washable filter-Use a vacuum cleaner or tap the filter
lightly for easy cleaning. If the filter is particularly dirty, use
warm water with a small amount of medium strength. (Fig.8)
• Make sure the filter is completely dry before replacing.
• Do not expose the filter to sunlight.
• For active carbon filter (Fig. 9.) - This filter is not washable. Its
life span is variable and depends on the ambient conditions
where the appliance is used. The filter should be checked
periodically (about every 6 months) and replaced if necessary.
STORAGE
If not use the unit for an extended period of time. Please:
• Turing the unit off, unplug and tidy AC cord.
• Completely empty the water tank and wipe it clean.
• Cover the unit and store where it will not receive direct
sunlight.
7. TROUBLE SHOOTING
THE UNIT DOES NOT OPERATE:
• Is the unit plugged in?
• Is the house electricity on?
correct
• Is the room temperature below 5
then it is out of the working range of the unit.
• Ensure the ON/OFF switch is turned on.
• Check the water tank is positioned properly in the unit and it is
not full.
• Make sure the air inlet and outlet are not obstructed.
THE UNIT SEEMS TO DO NOTHING:
• Is the filter dusty, contaminated ?
• Is the air intake or outlet blocked up?
temperature
button
will turn into red.
use
volatile
chemicals,
o
C or above 35