Methods for replacing UV lamp
Photo sensor is built-in the device, if the UV light is
very weak or not lighted, the UV icon on the product
operating panel will be flashing; it means UV lamp
should be replaced. The diagram as following:
Disassembly and installation for
UV lamp
Take off the filter cover, and take out all filters. then UV
lamp can be replaced. The diagram as following:
Disassembly of UV lamp
Hold the UV lamp and rotate it for 90 clockwise or
anticlockwise, then take it out.
Installation of UV lamp
Hold the UV lamp and rotate it for 90 clockwise or
anticlockwise, then install it well.
UV lamp function is optional, please refer to the actual
machine for configuration
12
Indicator for replacing
UV lamp
FAQ
If the machine can't work properly, please kindly check
as below before you send it out for repair.
Problem
Checking methods
Do not work
Please check if the
plug is
disconnected from
the socket.
Please check if the
filter cover is
installed
completely
Odor cannot
Is there a very
be removed
strong odor in the
using environment?
(Notes: air should
be purified
continuously)
Does the using life
time for activated
carbon filter come
to the end?
High noise
Is the PE bag for
filter removed?
Does the using life
time for HEPA
come to the end?
If the problem still existed after above inspections,
please disconnect the power and send it for repair.

TECHNICAL PARAMETERS

Filter parameters
Description
Size
HEPA
206 x 99 x 40 mm
Activated carbon
206 x 97 x 15 mm
+ photo catalyst
UV parameters
Description:
Model:
Power rating:
Voltage:
Wave length:
Life time:
Parameters of the unit
Voltage supply:
Air flow volume:
Noise level:
Length of power cord:
Product size:
Net weight:
Power rating:
Applicable area:
Solution
Power plug
should be
plugged properly
Recover the filter
cover correctly
Suggesting to
ventilate, then
start up the
machine.
Please replace
new filters.
Please take out
filters and tear
off PE bag.
Please replace
new HEPA.
Life time
About 12
months
About 6
months
UV lamp
T5
6 W
220∼240 V
254 nm
8000 h
220-240 V, 50 Hz
≥ 150 m
3
/h
≤ 40 dB(A)
≥ 1.4 m
328.8 x 170 x 300 mm
4 kg
36 W
25 m
2
(269 ft