MAINTENANCE
Safety warnings for maintenance
Maintenance of the stove must be performed at least once a year and should be planned in advance with the
Technical Assistance Service.
In some conditions, such as turning the stove on and off or inappropriate use, the combustion products can contain
small soot particles that build up in the smoke evacuation system. This can reduce the cross-section of the smoke
duct and pose a fire risk. The smoke evacuation system must be inspected and cleaned at least once a year.
The maintenance operations must be carried out when the stove is cold and with the electrical power supply
disconnected.
Before completing any maintenance operation, adopt the following precautions:
•
Make sure that all stove parts are cold.
•
Make sure that the ashes are completely cold.
•
Always operate with equipment that is appropriate for maintenance.
•
When maintenance is finished, re-install all of the dis-assembled parts before restarting operation.
The quality of the wood, the stove operating mode and combustion control can affect maintenance activity frequency.
Cleaning
Perform the cleaning operations so as to guarantee correct stove operation. The table below lists the necessary
cleaning operations required for correct stove operation.
PARTS / FREQUENCY
Combustion chamber
Combustion grille
Ash drawer
Glass
Extraction duct
Use and maintenance manual Calliope EU
1 DAY
•
•
•
2-3 DAYS
60-90 DAYS
•
•