Notice: The installation of unit must be done by professional staff; the improper installation may lead
to water leak, electric shock or fire hazard.
Field selection
Indoor unit
1.
1) It shall be installed at the place whether the air blown out can quickly spread the entire room and
with certain maintenance space.
2) The air inlet and outlet of indoor unit will not be obstructed and affected by heat and vapor generated
hereby.
3) Avoid installing at the place with large amount of fumes and vapors.
4) Avoid installing at the place with may generate, flow, stagnate or leak the inflammable gas.
5) Avoid installing near the devices which may generate high frequency, such as high frequency electric
welder.
6) Avoid installing the air exhaust near the fire alarm.
7) Avoid installing at the place where frequently use the acid solution.
2. Outdoor unit
1) Install at the place where can not be directly exposed to the sunshine (if inevitable, please mount the
sunshade facility to avoid direct exposure to the sunshine).
2) The noise and air flow generated by the unit will not affect the neighbor.
3) Convenient connection of indoor and outdoor unit and for ease of connection of power supply.
4) Do not install at the place where the inflammable gas may generate, flow, stagnate and leak.
5) During heating, the condensation drained out of outdoor unit chassis will not affect the neighbors or
passer-by.
Installation requirements and maintenance space (outdoor unit)
1. Single unit installation (unit: mm)
Above 300
When there is barrier at
upward side, if possible to
keep the space shown in the
figure, it does not matter even
if there is barrier at back.
3.Preparation before installation
Above 300
When the front side (outlet for exhaust) is
open, if it can keep the space shown in the
figure, it does not matter even if there are
(Open above)
barriers at three sides.
8
Above 300
Above 300
If there is barrier at the front side, the back,
both sides and upward side shall be kept
open.