3.2.14 Circuit Layout
3.3 Alarms
The sistem is equipped with the following alarm:
Low level alarm, with 5 seconds of Hysteresys. Low level alarm pH stops the
dosing of pH pump only (the same for Rx).
Flow alarm, with 5 seconds of Hysteresys. Flow alarm stops the dosing of both the
pumps (with Flow alarm on the Relè is always open).
Dosing alarm (see also 3.2.5). Dosing of product without effect (withou variation of
pH&Rx readings). Dosing alarms can be removed only with system restart (use
ON/OFF switch)
Measure alarm: the system is equipped with an adding alarm of pH reading, if the
reading of pH is lower than 5 or higher than 9 (WARNING), the system stops the
pumps. If the reading of pH is lower than 5 or higher than 9 it is recommended to
check the probe and the water.
4.0 Electrode winter break
Remove the electrodes during winter break. Fill in the protection cap with 1/3 of water and
put it on the electrodes.
§ It's recommended to install new electrodes every season begin §
5.0 Coming season start-up procedures
- It's recommended to install a new electrode when season begin, in order to prevent
failure during season.
- After the electrode replacement or start up of the apparatus, repeat the calibration
procedure.