Actuator (Receiver); Installation In A Flush-Mounted Socket - Intermatic Grasslin thermio essential H Srf Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

3.
Once you have set the hysteresis, wait five seconds until the switching differential symbol stops
flashing.
The room thermostat only regulates once the temperature falls below the temperature set-
ð
point by the amount of the hysteresis that was just set.

Actuator (receiver)

INSTALLATION IN A FLUSH-MOUNTED SOCKET

Personal:
Qualified electrician
Removing the housing cover
1.
Undo the screw connection on the device housing with the Phillips screwdriver and remove the
housing.
Connecting
2.
Strip the connection wires to a length of 8 mm (cross-section between 1 mm² and 2.5 mm²).
3.
Insert the connection wires into the corresponding terminals (Fig. 2/6) in accordance with the
wiring diagram (Fig. 7).
EN
59

Publicidad

Tabla de contenido
loading

Tabla de contenido